EN
13
EVENTS
You can set the several functions to be executed when specific events occur. Up to 20 events can be set.
EVENTS
•
No.:
select the progressive number of the event
•
Action:
select the action triggering the event
◊
None:
no action (default)
◊
Call sent:
if a call is sent to a door-entry phone with an address that falls within the values entered in
the
“From address”
and
“To address”
fields, it triggers the event specified in the “
Activation”
field
◊
Lock-release:
if a lock-release command is sent from a door-entry phone with an address that falls
within the values entered in the
“From address”
and
“To address”
fields, it triggers the event specified
in the
“Activation”
field
◊
Actuator control:
if an actuator command is sent with an address that falls within the values entered in
the
“From address”
and
“To address”
fields, it triggers the event specified in the “
Activation”
field
•
Activation:
action triggered after the event specified in the
“Action”
field occurs
◊
Local output control:
activates the output set in the
“Local output type”
field (SE output for the
module or Relay output for the module). NOTE: Module SE Output and/or module Relay Output must
be set in the menu “Outputs” > SE Output and/or Relay Output with “Function” > Lock-release and/or
actuator
◊
Control on Ultra bus (UDB):
activates the relay on the number keypad specified in the
“Device type”
field (UDB output type: Relay 1 or Relay 2)
◊
Actuator control:
activates the actuator with the address specified in the
“Address”
field (from 1 to
255)
•
Activation
◊
Local output control
(non-editable)
•
Local output type
◊
Relay
(non-editable)
•
Enable Tones:
a confirmation tone is emitted when the output is activated for the time period set in the
“Activation time (sec.)”
field
VIRTUAL OUTPUT 1 / VIRTUAL OUTPUT 2
•
Function:
select the command which activates the virtual output for the audio module. The virtual outputs
are NOT physically part of the module, they are commands sent over the bus.
◊
Lock-release:
every lock-release command activates the output
◊
Actuator control:
every actuator command with the address set in the
“Address sent to external unit”
field activates the output
◊
Call sent:
every call sent activates the output
•
Activation
◊
Local output control:
activates the output set in the
“Local output type”
field (SE output for the
module or Relay output for the module)
◊
Control on Ultra bus (UDB):
the command activates the relay on the Module keypad specified in the
“Device type”
field (UDB output type: Relay 1 or Relay 2)
◊
Actuator control: t
he command activates the actuator with the address entered in the
“Address”
field
•
Enable tones:
a confirmation tone is emitted when the output is activated for the time period set in the
“Activation time (sec.)” field