Comelit Simplebus2 UT2010 Technical Manual Download Page 7

7

Installation

A = Flush-mounted box
B = Rain shield 
C =  Flush-mounted module holder 

with finishing frame

Flush-mount

ed 

box

 

3110/1

 

3110/2

 

3110/3

 

3110/4

Rain shield

 

UT9181

 

UT9182

 

UT9183

 

UT9186

 

UT9189

 

UT9184

 

UT9188

Module holder/ finishing fr

ame

 

UT9161

 

UT9162

 

UT9163

 

UT9164

A =  Rain shield 
B =  Surface-mounted housing 

with frame

Rain shield

 

UT9191

 

UT9192

 

UT9193

 

UT9196

 

UT9199

 

UT9194

 

UT9198

Housing/fr

ame

 

UT9171

 

UT9172

 

UT9173

 

UT9176

 

UT9179

 

UT9174

 

UT9178

 Optional

The entrance panel is available in flush-mounted or surface-mounted variants:

Flush-mounted installation composition table

Surface-mounted installation composition table

Summary of Contents for Simplebus2 UT2010

Page 1: ...Passion Technology Design EN TECHNICAL MANUAL Simplebus2 Ultra audio module Art UT2010...

Page 2: ...wer cables 230V or higher Safe usage To ensure Comelit products are used safely carefully observe the indications provided in the Manuals Instruction sheets make sure the system created using Comelit...

Page 3: ...supply unit Art 1595 15 Connection of button modules Art UT9200 16 Connection of Touch screen module Art UT9270 16 Connection of numeric keypad module Art UT9279M 16 Variant with separate power supply...

Page 4: ...indications for disabled individuals assistance request can be activated via programming Facility for 2 call buttons To be finished with cap single button or dual button made using aluminium or profe...

Page 5: ...Addressing and programming Dip Switches 10 Microphone volume control 11 Programming confirmation button 12 Digital microphone Use screwdriver supplied 13 Terminal block for connection RTE programmabl...

Page 6: ...orption in standby W 1 5 Maximum absorption W 3 5 HARDWARE CHARACTERISTICS Call type Buttons Type of buttons Mechanical Number of buttons no 2 Backlighting colour White Off Terminals L L V V COM NC NO...

Page 7: ...dule holder finishing frame UT9161 UT9162 UT9163 UT9164 A Rain shield B Surface mounted housing with frame Rain shield UT9191 UT9192 UT9193 UT9196 UT9199 UT9194 UT9198 Housing frame UT9171 UT9172 UT91...

Page 8: ...8 2 1 2 UP 5 3 4 165 cm 130 cm 1 Flush mounted installation Optional BLACK RED Optional...

Page 9: ...odule 2B CLOSE The button has a nameplate which can be written on A alternatively an adhesive label can be applied B The total thickness of the nameplate adhesive label must not exceed 0 2 mm You can...

Page 10: ...10 Installation with side by side boxes Before installing the boxes in the wall fit the spacers...

Page 11: ...11 165 cm 130 cm 2 UP 5 3 4 UP 1 2 3 1 Wall mounted installation Optional Optional BLACK RED...

Page 12: ...module 2B The button has a nameplate which can be written on A alternatively an adhesive label can be applied B The total thickness of the nameplate adhesive label must not exceed 0 2 mm You can visit...

Page 13: ...13 Installation with side by side boxes...

Page 14: ...DC 12V 24V 1210A 1210 ON 1 2 3 4 6 7 5 8 UT2010 UT2010 Connections UT2010 connections UT2010 connections with separate power supply Max 20 m Local door opener button Max 20 m Local door opener button...

Page 15: ...utdoor entrance panel module consumption table Code Consumption mA UT9200 Call button modules 12 5 UT9240 Information module 12 5 UT9240M Metal information module 12 5 UT9279M Numeric keypad module 40...

Page 16: ...A 1210 UT9279M E T R GND SE SE NO NC C O M L L V V UT2010 Connection of button modules Art UT9200 Connection of Touch screen module Art UT9270 Variant with separate power supply Connection of numeric...

Page 17: ...1 1 2 4 22 2 3 5 TAB A Configure button type single dual DIP 6 configuring button type Single button DIP6 ON Dual button DIP6 OFF default I Address button modules DIP 1 5 addressing call button module...

Page 18: ...is complete make sure the button configuration is correct single dual see Configure button type single dual Take note of the DIP switch settings example code 1 Set the address of the apartment you wi...

Page 19: ...lete make sure the button configuration is correct single dual see Configure button type single dual Take note of the DIP switch settings example code 25 example code 37 example code 70 example code 5...

Page 20: ...tch settings 1 Set the dip switches in accordance with the function you wish to program see table 2 Press the confirm button Reset the configuration of the DIP switches When programming is complete ma...

Page 21: ...ommand 4 sec 231 1 2 3 6 7 8 C NC NO relay activation on actuator command 8 sec Door lock 245 1 3 5 6 7 8 Door lock time 2 sec disabling tone default 246 2 3 5 6 7 8 Door lock time 4 sec 247 1 2 3 5 6...

Page 22: ...ess of the buttons see Adjusting the brightness of the button LEDs 162 2 6 8 Light me OFF default 163 1 2 6 8 Light me ON the button LEDs for the audio video module are always on and when the button i...

Page 23: ...ation of the start up phase 10 seconds maximum In AUTO mode the twilight sensor checks the ambient light level every 9 minutes if the measured values exceed the specified minimum maximum thresholds it...

Page 24: ...If it is daytime and you want to check AUTO mode operation for the twilight sensor you can proceed as follows 1 Enter programming mode 2 Block the twilight sensor for 5 seconds If AUTO mode has been s...

Page 25: ...ess a button repeatedly for each module to change the individual brightness of the buttons Reset the configuration of the DIP switches When programming is complete make sure the button configuration i...

Page 26: ...ion button backlighting is only enabled on the user s request by pressing the LIGHT ME button on the audio video module this saves energy and reduces light pollution Backlighting management for this b...

Page 27: ...ing settings 3 Press the confirm programming button the green lock release LED will start flashing at the end of the backup approx 30 sec the green lock release LED switches off the green audio enable...

Page 28: ...ble to download free of charge from pro comelitgroup com You will need a USB micro USB cable Errors and indications INDICATION SOLUTION RED LED LIT STEADILY DISSUASION TONE Line short circuit Check co...

Page 29: ...2 7 8 224 6 7 8 15 1 2 3 4 45 1 3 4 6 75 1 2 4 7 105 1 4 6 7 135 1 2 3 8 165 1 3 6 8 195 1 2 7 8 225 1 6 7 8 16 5 46 2 3 4 6 76 3 4 7 106 2 4 6 7 136 4 8 166 2 3 6 8 196 3 7 8 226 2 6 7 8 17 1 5 47 1...

Page 30: ...1st edition 09 2020 code 2G40002538 w w w c o m e l i t g r o u p c o m Via Don Arrigoni 5 24020 Rovetta BG Italy C E R T I F I E D M A N A G E M E N T S Y S T E M S...