The front panel

1

2

3

4

5

6

7

1.  16 x 2-character LCD.

2.  LED indicators: green, orange, red.

3. Alphanumeric 

keypad.

4. Arming/disarming 

buttons.

5. Back/Cancel/Delete 

button.

6. Enter/Confi rm button.

7.  Navigation keypad / menu button.

• 

Green LED: indicates the system is armed
(lit steadily) or in
“not ready to arm” condition (fl ashing). The LED is off  if the 
system is ready for arming.

• 

Orange LED: indicates a fault (lit steadily) or isolated / 
bypassed zones (fl ashing).

• 

Red LED: indicates an alarm / tampering in progress (lit 
steadily) or an alarm in the memory (fl ashing).

Viewing the system status

System ready to arm - Single area

System armed - Single area

System not ready to arm - Single area

Flashing

System ready to arm - 4 areas

System armed - 4 areas

System not ready to arm - 4 areas

Flashing for areas not ready to arm

Exit delay - single area

Entry delay - single area

Entry and exit delay - 4 areas

Countdown

The control panel has a display that can show the system status. The pictures below illustrate the various messages based on the system status.

The messages on the display change depending on whether the system is used to monitor a single area or several areas. In the latter case (multi-area), the bottom 
line of the display is divided into four to display the status of each individual area (only existing areas are actually shown). See below for the diff erences between 
single area and multi-area displays:

Countdown

Countdown

System part armed - Single area

System part armed - 4 areas

Summary of Contents for HUB32LCD

Page 1: ...EN USER MANUAL Quick start user manual for wireless intruder alarm control panel HUB32LCD Passion Technology Design...

Page 2: ...the alarm system 5 Disarming the alarm system 5 Forced arming 5 Custom area arming 6 Show open zones faults 6 Show bypassed zones 6 System in alarm 6 Silencing an alarm Alarm Memory 7 Generating a re...

Page 3: ...the few seconds prior to the intruder event The control panel has a built in microphone and speaker which allow users to call rooms from a remote telephone and start a hands free two way audio convers...

Page 4: ...em not ready to arm Single area Flashing System ready to arm 4 areas System armed 4 areas System not ready to arm 4 areas Flashing for areas not ready to arm Exit delay single area Entry delay single...

Page 5: ...s armed and all detectors trigger an alarm if violated according to their con guration Note that some devices such as ooding and smoke detectors trigger an alarm regardless of the arming status Part a...

Page 6: ...arm and the green LED will ash The X button will show the list of open zones which will scroll automatically 2 seconds for each zone You can scroll through the list manually using the Down arrow 2 Se...

Page 7: ...installer The siren begins to sound the red LED on the control panel is lit steadily and the alarm alert is displayed If the zone is reset the control panel will show the message System in alarm ashi...

Page 8: ...cedure Exclusion prevents the violation of these zones from triggering an alarm The same menu can be used to isolate a zone this prevents that zone from generating any messages including the tampering...

Page 9: ...ge LED starts ashing rapidly While it is ashing press button 4 once The red LED will con rm locking The green LED will con rm unlocking LED indications Button pressed Short red ash Command executed tw...

Page 10: ...nd down arrows on the navigation keypad See below for a diagram illustrating navigation within the Event log Each event has applicable attributes EventQual Event qualifier R for Reset Empty for activa...

Page 11: ...11...

Page 12: ...1st edition 12 2020 code 2G40002607 w w w c o m e l i t g r o u p c o m Via Don Arrigoni 5 24020 Rovetta BG Italy CERTIFIED MANAGEMENT SYSTEMS...

Reviews: