The Comelit smoke generator is an accessory for alarm systems to be used on generic wired alarm 

systems.

The main purpose is to set up a deterrence system during theft or robbery events activating both 

a high-potential piezoelectric siren and a smoke generator that is able to fill an environment up to 

100 cubic meters in about 30 seconds.

•  Do not install the equipment in areas used for food production, storage and/or 

supplying.

•  Do not install the equipment in areas used for the production and/or storage of 

goods for which even slight dust contamination is not admissible.

•  Do not install the equipment in rooms where people and/or animals that cannot 

escape in case of smoke release may be present.

•  Do not install the equipment in such a way as to make it difficult and/or dangerous 

to leave the premises in case of smoke release.

•  Once the smoke generator is activated, it is not possible to interrupt the delivery 

which lasts until the content is exhausted.

•  In the event of activation, ventilate the premises within 1 hour of smoke release.
Comelit Group S.p.A. declines all responsibility in the event of non-compliance with 

the instructions given in this manual and in the Safety Information.

Operation

The device can be connected to an alarm system via an electrical cable connection that can reach 

a maximum distance of 200 meters.

The smoke generator consists of a sturdy plastic enclosure where the electronic control circuit, 

the piezoelectric siren and the smoke generator accompanied by its own activation circuit are 

housed inside. The electronic circuit is equipped with an 8-pole removable terminal block where 

the following connections are present:

•  VCC    

 

 

power supply (positive polarity)

•  Start Smoking Input  

 

programmable startup mode

•  Start Siren Input  

 

programmable start mode

•  Tamper / Anti-tear Output   

NC contact referred to GND with closed enclosure.

•  Used-up smoke generator   

NC contact referred to GND with full smoke generator

•  Error Output  

 

 

NC contact referred to GND with regular operation

•  GND    

 

 

power supply (negative polarity) and voltage reference  

 

   for 

inputs

The device allows an easy installation by indicating in real time the state of the apparatus by 

lighting a multicolored LED. In order to avoid unwanted activations of the smoke generator during 

installation, the apparatus recognizes the tamper opening and after 15 seconds enters “TEST and 

MAINTENANCE” mode. At this stage, the activation of the smoke generator is disabled and any 

accidental activation is diverted to the siren sound. This function can also be used as a system 

test. The exit from the “TEST and MAINTENANCE” state is obtained 15 seconds after closing the 

enclosure with the TAMPER and the anti-tear switches (if enabled) in closed position. A power 

range of 3Vcc to 15 Vcc and a low current drain of about 200μA in the idle mode, allow you to use 

the device in any security system.

Summary of Contents for FG100F

Page 1: ...IT MANUALE TECNICO EN TECHNICAL MANUAL FR MANUEL TECHNIQUE Passion Technology Design Art FG100F...

Page 2: ...4 Rimozione 14 Generalit Si invita prima di tutto a leggere attentamente le Informazioni sulla Sicurezza che sono state fornite in formato cartaceo a corredo del prodotto al momento della vendita Come...

Page 3: ...costituito da un robusto contenitore plastico dove al suo interno sono alloggiati il circuito elettronico di controllo la sirena piezoelettrica e il Generatore di fumo corredato dal proprio circuito...

Page 4: ...l alimentazione Tale autonomia garantisce che il dispositivo sia regolarmente funzionante fino a 4 ore dopo la perdita di alimentazione Uscita Tamper e Antistrappo NC contatto riferito a GND Antistra...

Page 5: ...atore di fumo Connettore Circuito elettronico e contenitore fumogeno 1 4 2 5 3 6 1 Tamper 2 Connettore di collegamento alla cartuccia 3 Sirena Piezoelettrica 4 Pulsante di reset 5 Dip Switch programma...

Page 6: ...geno e Funzione di avvio della sirena per la programmazione SW 4 Tempo sirena ON Segue input sirena OFF 60 secondi Default SW 5 Antistrappo ON Abilitato Default OFF Disabilitato SW 6 Funzione AND ON A...

Page 7: ...geno l ingresso IN FUM deve essere portato nello stato di allarme mentre l ingresso IN SIR si trova gi nello stato di allarme Lo stato di allarme dell ingresso IN FUM programmabile tramite gli switch...

Page 8: ...o un positivo ON ON SW 3 SW 1 IN FUM Vhi 3 15Vcc Stato a riposo ingresso IN FUM in stato logico 1 contatto chiuso a tensione superiore alla tensione minima di stato logico 1 IN FUM Vhi 3 15Vcc Stato a...

Page 9: ...re attenzione deve essere posta con le configurazioni Positivo e Negativo a TOGLIERE Queste sono le possibili combinazioni e le corrispondenti modalit di funzionamento Positivo a dare Normalmente aper...

Page 10: ...alla tensione minima di stato logico 1 IN SIR Vhi 3 15Vcc Stato allarmato ingresso IN SIR con contatto aperto Negativo a togliere Normalmente chiuso verso un negativo ON ON SW 3 SW 2 IN SIR GND Stato...

Page 11: ...mmediatamente quando l ingresso IN FUM viene allarmato Tamper antiapertura e antistrappo Il tamper antiapertura e antistrappo fanno riferimento ad una unica uscita OUT TAMP con riferimento a massa nel...

Page 12: ...ronto all attivazione Passo n 3 t 3 s singolo lampeggio Verde Entrambi gli ingressi Fumogeno e Sirena sono in stato di riposo nessun allarme Rosso Almeno uno dei due ingressi attivato allarme Passo n...

Page 13: ...assaggio dell ingresso IN FUM nello stato di attivazione provoca un suono CONTINUO della sirena della durata di 3 secondi abbinato al lampeggio veloce del LED ROSSO Il passaggio dell ingresso IN SIR n...

Page 14: ...e di fumo mediante l apposito connettore e posizionarla nell alloggiamento Verificare lo stato del generatore di fumo con i 3 lampeggi LED VERDE ad indicare lo stato di REGOLARIT Chiudere il coperchio...

Page 15: ...a regola d arte per errata o carente manutenzione secondo quanto indicato nelle relative istruzioni d uso o comunque secondo l usuale manutenzione per operazioni o uso improprio o errato per trascurat...

Page 16: ...General information The product and this manual must be examined before performing any operation The information in this manual was verified during the writing of the manual itself however Comelit Gr...

Page 17: ...ce of 200 meters The smoke generator consists of a sturdy plastic enclosure where the electronic control circuit the piezoelectric siren and the smoke generator accompanied by its own activation circu...

Page 18: ...es that the device is regularly functional up to 4 hours after the power loss Tamper and anti tear output NC contact connected to GND Anti tear can be disabled with J2 jumper Continuous supervision of...

Page 19: ...oke generator cartridge Connector Electronic circuit and smoke generator enclosure 1 4 2 5 3 6 1 Tamper 2 Smoke generator connection cable 3 Piezoelectric siren 4 Reset button 5 Programming Dip Switch...

Page 20: ...function for programming SW 4 Siren time ON Follow siren input ON time OFF 60 seconds Default SW 5 Anti tear ON Enabled Default OFF Disabled SW 6 AND function ON Enabled Default OFF Disabled SW 7 Led...

Page 21: ...ut must be brought to the alarm state while the IN SIR input is already in the alarm state The alarm status of the IN FUM input can be programmed using the SW 1 and SW 3 programming switches WARNING I...

Page 22: ...closed at voltage lower than the maximum voltage of logic state 0 ON ON SW 3 SW 1 IN FUM Vhi 3 15Vcc IN FUM Vhi 3 15Vcc Rest state IN FUM input in logic state 1 contact closed at voltage higher than...

Page 23: ...tion must be paid with the Positive and Negative to REMOVE configurations These are the possible combinations and the corresponding operating modes Positive to give Normally open to a positive Negativ...

Page 24: ...Rest state IN SIR input in logic state 1 contact closed at voltage higher than the minimum voltage of logic state 1 Alarmed state IN SIR input with open contact ON ON SW 3 SW 2 IN SIR GND IN SIR GND...

Page 25: ...enerator is activated immediately when the smoke input IN FUM is alarmed Anti opening and anti tear Tamper The anti opening and anti tear tamper refer to a single OUT TAMP output In Normal state close...

Page 26: ...s ready for activation 3rd step t 3 s single blink Green Both Smoke and Siren Inputs are in Normal state No Alarm Red One or both Inputs are active Alarm state 4th step t 4 5 s single blink or no blin...

Page 27: ...in this mode a single BLUE flash blinks every 3 seconds the smoke emission is disabled if the IN FUM input is activated alarm condition the siren emits a CONTINUOUS sound and the RED LED blinks rapid...

Page 28: ...smoke generator cartridge and place it in position Check the status of the smoke generator 3 GREEN blinks to indicate the REGULAR status Close the lid with the screws provided Insert the screw cover...

Page 29: ...g the same installation carried out in an unprofessional manner wrong or poor maintenance interventions in accordance with what is indicated in the relevant operating instructions or according to usua...

Page 30: ...r de fum es 42 Assembl e 42 Retrait 42 INDEX G n ralit s G n ralit s Tout d abord nous vous invitons lire attentivement les informations de s curit fournies au format papier et accompagnant le produit...

Page 31: ...male de 200 m tres Le fumig ne se compose d un r cipient en plastique robuste o le circuit de contr le lectronique la sir ne pi zo lectrique et la g n rateur de fum e accompagn e de son propre circuit...

Page 32: ...ette autonomie garantit que l appareil est en fonctionnement r gulier jusqu 4 heures apr s la coupure de courant Sortie de Tamper et Anti enl vement N C r f r au contact GND Anti tear d sactiv via SW...

Page 33: ...necteur Circuit lectronique et r cipient de fum e 1 4 2 5 3 6 1 Tamper 2 Connecteur de connexion la cartouche de g n rateur de fum e 3 Sir ne pi zo lectrique 4 Bouton de r initialisation 5 Switch de p...

Page 34: ...Fonction de d marrage sir ne pour la programmation SW 4 Dur e de la sir ne ON L entr e de la sir ne suit OFF 60 secondes Default SW 5 Anti enl vement ON Activ Default OFF D sactiv SW 6 Fonction AND O...

Page 35: ...IN FUM doit tre amen e l tat d alarme alors que l entr e IN SIR est d j en tat d alarme L tat d alarme de l entr e IN FUM est programmable l aide des commutateurs de programmation SW 1 et SW 3 ATTENT...

Page 36: ...erm une tension inf rieure la tension maximale de l tat logique 0 ON ON SW 3 SW 1 IN FUM Vhi 3 15Vcc IN FUM Vhi 3 15Vcc Etat de repos entr e IN FUM l tat logique 1 contact ferm une tension sup rieure...

Page 37: ...gement de fum e Une attention particuli re doit tre accord e aux configurations positive et n gative ENLEVER Voici les combinaisons possibles et les modes de fonctionnement correspondants Positif de d...

Page 38: ...de repos entr e IN SIR l tat logique 1 contact ferm une tension sup rieure la tension minimale de l tat logique 1 tat d alarme entr e IN SIR avec contact ouvert ON ON SW 3 SW 2 IN SIR GND IN SIR GND t...

Page 39: ...lorsque l entr e IN FUM est en alarme Tamper anti ouverture et anti enl vement L anti ouverture et anti enl vement inviolable se r f rent une seule sortie OUT TAMP avec r f rence de masse dans la posi...

Page 40: ...L appareil est pr t tre activ Point n 2 t 3 s flash unique Vert Les deux entr es fum e et sir ne sont au repos pas d alarme Rouge Au moins une des deux entr es est activ e alarme Point n 4 t 4 5 s fla...

Page 41: ...onnement de l entr e IN FUM l tat activ provoque un son CONTINU de la sir ne d une dur e de 3 secondes combin au clignotement rapide de la LED ROUGE Le positionnement de l entr e IN SIR l tat activ pr...

Page 42: ...fum e par le connecteur appropri et la positionner dans le bo tier V rifier l tat du g n rateur de fum e avec les 3 clignotements de la LED VERT pour indiquer l tat de R GULARIT Fermez le couvercle a...

Page 43: ...nt relatives ou en l absence de celles ci non effectu es dans les r gles de l art des erreurs ou des carences d entretien au regard de ce qui est indiqu dans les instructions d utilisation ou de toute...

Page 44: ...w w w c o m e l i t g r o u p c o m Via Don Arrigoni 5 24020 Rovetta BG Italy C E R T I F I E D M A N A G E M E N T S Y S T E M S...

Reviews: