Terminal 1 -
Marked “+” (+12V) - Connect to a positive Voltage of 9.6 -16Vdc source
(Usually from the alarm CP)
Terminal 2 -
Marked “-” (GND) - Connect to the ground of the CP.
Terminal 3
–Marked "Test" 9.6-16 v on this pin will enter the DT12EAM to walk test mode
even if SW2 position 1 is off
Terminals 4 & 5 -
Marked “ALARM” - These are the output relay contacts of the detector.
Connect to a normally closed or normally opened zone in the control unit. When an
intruder is detected, alarm relays (N.C. and N.O.) will switch for 1.8 sec.
Terminal 6&7 -
Marked “AM/FAIL" These are the output of the anti mask and Trouble relay
(N.C. and N.O.) Will switch if one from the following scenario happens:
The supply voltage is under 8.5v
Mask detection (will restore if the mask is removed)
PIR or MW self test fail (every 10 hours the detector made self test for PIR and MW
sensors)
Terminal 8 -
Marked “TEOL” - End of line – optional terminal for end of line resistors
connections.
Terminals 10 & 9 -
Marked “TAMPER” - If a Tamper function is required connect these
terminals to a 24-hour normally closed protective zone in the CP.
If the top cover of the detector is opened or the detector is detached from installation wall,
an immediate alarm signal will be sent to the CP.