![Comelit DT12EAM Manual Download Page 15](http://html1.mh-extra.com/html/comelit/dt12eam/dt12eam_manual_2640383015.webp)
12 Specifications
Detection Method
PIR AND MW
Microwave Frequency
10.525GHz
Power Input
9.6 to 16Vdc
Current Draw
Active: 24mA (±5%)
Standby: 21mA (±5%)
Temp Compensation
Dual slop temperature compensation
Alarm Period
2 sec (±0.5sec)
Alarm Outputs
Form C (NC, NO, Common)
28Vdc 0.1 A with 10 Ohm
Tamper Switch(s)
Two Switches
N.C 28Vdc 0.1 A with 10 Ohm Series protection resistors
Opens when cover is removed from unit’s base
Warm up Period
30sec (± 5sec)
RF Immunity
10 V/m plus 80% AM from 80 MHz to 2GHz
Electrostatic Immunity
6kV contact, 8kV air
Transient Immunity
1kV
Operation Temp
-35ºC ~ +55ºC
Dimensions
160 mm x 70 mm x 45 mm
Weight
210gr.
European directives
RTTE , EMC, Low Voltage, RoHS
USA & Canada
47CFR part 15, subpart C, section 15.245, 47CFR part 15,
subpart B
RSS210, ICES-003
Protection Degree
IEC 60529: IP 64
* Specifications are subject to change without prior notice
.