13
229
1,3,6,7,8
C.NC.NO relay activation on actuator command: 2 sec
230
2,3,6,7,8
C.NC.NO relay activation on actuator command: 4 sec
231
1,2,3,6,7,8
C.NC.NO relay activation on actuator command: 8 sec
Door lock
245
1,3,5,6,7,8
Door lock time: 2 sec + disabling tone (default)
246
2,3,5,6,7,8
Door lock time: 4 sec
247
1,2,3,5,6,7,8
Door lock time: 8 sec
248
4,5,6,7,8
Door lock confirmation tone: enabled
251
1,2,4,5,6,7,8
Relay C.NC.NO in parallel to SE (default)
252
3,4,5,6,7,8
Lock-release always enabled (default)
253
1,3,4,5,6,7,8
Lock-release only enabled for user called
System functions
232
4,6,7,8
Awaiting response time: 60 sec (default)
233
1,4,6,7,8
Awaiting response time: 120 sec
234
2,4,6,7,8
Awaiting response time: 30 sec
235
1,2,4,6,7,8
Talk time: 90 sec. (default)
236
3,4,6,7,8
Talk time: 180 sec
239
1,2,3,4,6,7,8
Confirmation tone on user call = enabled (default)
240
5,6,7,8
Confirmation tone on user call = disabled
243
1,2,5,6,7,8
Awaiting reset time: 10 sec (default)
244
3,5,6,7,8
Awaiting reset time: 1 sec
208
5,7,8
Reset after lock-release in audio: enabled (default)
209
1,5,7,8
Disables “awaiting reset time” on lock-release command (awaiting response time or talk
time will be activated).
249
1,4,5,6,7,8
Call transmission: single (default)
250
2,4,5,6,7,8
Call transmission: triple
System mode
0
Simplebus (default)
255
1,2,3,4,5,6,7,8
Simplebus Top
254
2,3,4,5,6,7,8
Restore default
Operating notes
• When a call is transmitted from the external unit, if a busy tone is heard instead of the ringtone, this means communication
with another external unit is in progress.
System performance and layouts
For further information of system performance and to view installation layouts, click on the system type that best meets your
requirements:
•
for the creation of audio-video systems for
individual residences
.
•
for the creation of audio systems for
residential complexes.