background image

 

 

4.2 System Information 

 

  When enter the OSD, it display SYSTEM, you will see: 

 

MFG

: Max 15 characters displayed on the screen. 

PROTOCOL

: Display the protocol of the dome 

DOME ID

: Display the dome address 

COMM

: Baud rate. 

TEMPERATURE

: Display the temperature of the camera, it changes along with the 

temperature of the camera, the data is unchangeable manually.   

VERSION

: Version will update along with the product upgrading 

Remark: 

Protocol, ID and COMM all can be set in menu <COMM>. 

4.3 Dome 

 

 

 

 

 

 

 

 

 

 

 

 

<SYSTEM>

 

MFG                         
PROTOCOL                            PELCO D-P 
DOME ID    

                                    001 

COMM 

                                  2400.N.8.1     

TEMPERATURE                              41.8

 

VERSION                      V863R15122109 
EXIT 

<DOME

>

 

<COMM> 
<IR DISPLAY> 
<GUARD TOURS> 
<A-B SCAN> 
<PAN SCAN> 
<PATTERN> 
<PARK ACTION > 
<PRIVACY ZONE> 
<ADVANCED> 
EXIT 

<MAIN MENU> 

 
<SYSTEM> 
<DOME> 
<CAMERA> 
<DISPLAY> 
<LANGUAGE> 
<TIMING TASK> 
<ALARM> 
<RESET> 
EXIT 

Summary of Contents for AHPTZ122IRA

Page 1: ...DOME IR PTZ AHD ART AHPTZ122IRA Please read this manual thoroughly before use and keep it for future reference ...

Page 2: ...g flash with arrowhead symbol within an equilateral triangle is intended to alert the user the presence of non insulated dangerous voltage within the product s enclosure that maybe of sufficient magnitude to constitute a risk of electric shock to different persons The exclamation point within an equilateral triangle is intended to alert the user the presence of important operating and maintenance ...

Page 3: ...ve or disassemble any internal parts of the video camera to avoid normal operation and possibly void the warranty There are no serviceable parts inside the camera All electrical connections to the dome should be made in strict accordance with the attached labels and wiring instructions in this manual Failure to do so may damage the dome beyond repair and void the warranty For outdoor installation ...

Page 4: ...damaged in any way when liquid traces are present or the presence of loose objects is evident or if the device does not function properly or has received sever impact or has been dropped accidentally 11 Indoor dome is for indoor use only and not suitable for outdoor or high humidity locations Do not use this product under circumstances exceeding specified temperature and humidity ratings 12 Avoid ...

Page 5: ...0 2 2 4 Ceiling Mounted 12 2 3 Installation of Brackets 13 2 2 1 Wall Mounted 13 2 2 2 Corner Mounted 14 2 2 3 Pole Mounted 15 2 2 4 Ceiling Mounted 16 2 4 Connection 17 3 Function Instruction 18 3 1 Power Up Action 18 3 2 Basic Function 19 3 3 Shortcut commands 19 3 4 Screen Character Operation 20 4 OSD Menu 19 4 1 Menu Index 19 4 2 System Information 20 4 3 Dome 20 4 3 1 Communication 23 4 3 2 I...

Page 6: ...ge 31 Appendix Ⅱ Clean Transparent Cover 30 Appendix Ⅲ Common Knowledge on RS 485 Bus 30 1 Basic Feature of RS 485bus 30 2 Mode of Connection and Terminal Resistance 30 Appendix Ⅳ Exception Handling 31 Copyright Statement 32 Indicates the functions with default protocol it might not function by using other protocols Indicates the optional functions only with certain mode ...

Page 7: ...1 Product Introduction 1 1 Package Contents IR Speed dome 1pc Wall mount bracket 1pc Power supply 1pc Screws kits 1pc User manual 1pc ...

Page 8: ...ble Pattern Scan 4pcs Pattern Scan Record Max 512 commands PWR On Action Memory Pattern1 Tour 1 360 scan A B scan Home None Park Mode Pattern 1 Tour1 360 scan A B scan Home None Park Time 1 60mins setting available Menu English Espanol Francais Portugues Polski Deutsch Italiano and so on Pan and Tilt position display Support Communication protocol Pelco D Pelco P Baud Rate 1200 2400 4800 9600bps d...

Page 9: ... targets such as wall 7 Targets are too dark or faint BLC If a bright backlight is present the target in the picture may appear dark or as a silhouette BLC enhance the target in the center of the picture the dome uses the center of the pictures to adjust the iris If there is a bright light source outside this area it will wash out to white the camera will adjust the iris so that the target in the ...

Page 10: ...reset is called Guard Tour Dome patrol scans according to certain edited preset order Power Off Memory This feature allows the dome to resume its previous preset or status after power is restored By default setting the dome support power up memory which improves the reliability and avoids repeated settings of the parameter Park Action If users don t operate the dome in set time it will automatical...

Page 11: ...void losses of cable causing low voltage and keep the dome work properly when processing wiring please refer to the requirement below Cable diameter 0 5mm 20 1 0mm 18 1 5mm 16 2 5mm 14 Dome distance 11m 37ft 18m 60ft 29m 95ft 46m 152ft For example if a dome is 35 meters away from the power power cable used must be more than 2 5mm otherwise the dome may suffer insufficient power supply and could no...

Page 12: ...2 2 2 Corner Mounted Bracket 2 2 3 Pole Mounted Bracket 2 2 4 Ceiling Mounted ...

Page 13: ...l expansion bolt in indoor and outdoor environment The wall can bear at least 4 times the weight of the dome Install wall hanging bracket a As shown in fig 2 with the installation holes in the underside of the wall hanging bracket as pattern draw punched locations and punch Fig 2 b As shown in Fig 3 fix the wall hanging bracket on the wall with wire and cable through it Fig 3 ...

Page 14: ...ht of the dome Install corner mounted attachment and wall hanging bracket a As shown in Fig5 with the installation holes in the corner mounted attachment as pattern draw punched locations on the wall with an angle of 90 and punch to install expansion bolt Fig 5 b As shown in Fig 6 use M8 screw nut to fix the base of corner mounted on the wall with all cables through the center holes of the corner ...

Page 15: ...tions Pole mounted dome can be used in the hard pole structure in indoor and outdoor environment whose diameter should match the installation size of stainless hose clamps Factory default is 6 inches stainless hose clamps fit φ130 152mm pillar The pole structure can bear at least 4 times the weight of the dome Install corner mounted attachment and wall hanging bracket ...

Page 16: ... through it on the pole structure Fig 9 b As shown in Fig 10 fix the wall hanging bracket with all cables through it on the pole mounted attachment Fig 10 2 3 4 Ceiling Mounted Fig11 Installation conditions Ceiling mounted dome with thick pole can be used in the hard ceiling structure whose thickness ...

Page 17: ...recessing seal groove of the ceiling connector bottom and through the core hole of the base of ceiling mounted Fix the base of hang ceiling on the ceiling board Fig 13 Note If the dome is used in the outdoor conditions use the silica gel on the faying surface of the base of hang ceiling and the ceiling board and around the out holes to be sure water proof c As shown in the Fig 14 tighten the boom ...

Page 18: ... Up Self Testing Pan Tilt Camera Self test Completion Lens action Lens zooms out to the widest angle Pan action Pan rotate in certain direction and stop in zero coordinate Tilt action Tilt rotate in certain direction and stop in zero coordinate From running the action above to power up mode completion power up self testing finishes SYSTEM MFG PROTOCOL AUTO DOME ID COMM TEMPERATURE VERSION PAN XXX ...

Page 19: ...Setting preset to press buttons preset number enter Calling preset to press buttons call number enter Deleting preset to press buttons clear number enter Remark Some preset points are occupied by special functions 3 3 Shortcut commands Below is list of shortcut commands user can enable the function by shortcut command easily Call PREST FUNCTION Call PRESET FUNCTION 16 OSD on Call twice 86 BLC on 3...

Page 20: ...cter Operation Call preset 95 to enter the OSD call preset 94 to exit the OSD Up or Down Move the option of the OSD change the optional on the OSD Right Enter the option select the item or confirm Left Return to main menu or cancel Angle Display XXX XX pan XXX XX tilt IR Display Display on the lower right corner of the screen Remark 1 Items with mean they have sub menu 2 means the cursor selecting...

Page 21: ...4 OSD Menu 4 1 Menu Index ...

Page 22: ...ong with the temperature of the camera the data is unchangeable manually VERSION Version will update along with the product upgrading Remark Protocol ID and COMM all can be set in menu COMM 4 3 Dome SYSTEM MFG PROTOCOL PELCO D P DOME ID 001 COMM 2400 N 8 1 TEMPERATURE 41 8 VERSION V863R15122109 EXIT DOME COMM IR DISPLAY GUARD TOURS A B SCAN PAN SCAN PATTERN PARK ACTION PRIVACY ZONE ADVANCED EXIT M...

Page 23: ... and restart SAVE After saving the dome will reboot Communication setting take effect 4 3 2 IR Display WORKING MODE Working mode has auto black white color selectable Default is auto TESTING TIME On IR auto working mode and the programmed time the IR will execute programmed action accordingly eg Switch from day to night or from night to day The detection time is from 2s to 15s selectable OUTPUT PO...

Page 24: ...zoom value option from 01 10 4 3 3 Guard Tours GUARD TOUR Total 8 guard tours selectable SETTING Each guard tour includes max 16 presets The number of the preset is from 0 64 but 0 is not valid Dwell time is 1 to 60s selectable Speed is 1 to 64 grade selectable INIT After initial preset point dwell time and speed will resume to default setting RUNNING Running the present guard tour DELETE Delete t...

Page 25: ... 0 While the exact preset point information doesn t be deleted So it is convenient for user to select the preset point needing to be scanned Speed and dwell time will reset as default setting 4 3 5 Pan Scan PAN SCAN SPEED Pan scan speed is 1 to 64 grade selectable INIT Reset the scan speed and tilt degree as default setting RUNNING Running the scan speed and tilt degree set 4 3 6 Pattern PAN SCAN ...

Page 26: ...m will remind that Please set park action DELETE Delete the settings 4 3 8 Privacy Zone not available yet 4 3 8 1 4 3 8 2 4 3 8 3 MASK NO Mask No depends on the number of the module supported MASK Mask has on and off selectable SETTING Set the specific parameter of present mask NO And call preset 1 to save the settings Direction operation Modify the coordinate of dome Zoom operation Modify the siz...

Page 27: ...atus AUTO FLIP Auto flip can be set as ON or OFF status OTHERS Set other options WIPER MODE WIPER MODE is On or Off status WIPER SPEED Wiper speed 1 5 level adjustable WIPER TIME Wiper time 1 5 times adjustable 4 4 Camera CAM Display the information of module supported by this dome ZOOM SPEED Zoom speed is quick and slow selectable DIGITAL ZOOM Digital zoom is on off selectable FOCUS Focus is auto...

Page 28: ...reset Save preset Call park action Pan scan etc User can enable or disable it DOME ID At the top left corner of screen it displays the dome ID User can enable or disable it COMM At the top left corner of screen it displays the dome communication information User can enable or disable it TIME Displays the current time on screen 4 6 Language LANGUAGE Language can be set as English Espanol Francais P...

Page 29: ...and preset point 1 8 selectable ALARM OUT Alarm out has NC normal close and NO normal open selectable RELEASE TIME Alarming release time 0 59s selectable the default is OFF PATROL TIME Patrol time is 0 59s selectable The default is 6s TIMING SETTING TIME YEAR 2016 TIME MONTH 01 TIME DATE 06 TIME HOUR 15 TIME MIN 34 TIME SEC 56 SAVE EXIT TIMING TASK START END FUNCTION 00 00 00 00 OFF 00 00 00 00 OF...

Page 30: ...l This product has built in fan and heater which accordingly cool or heat through temperature sensitive circuit inside the dome RESET DOME RESTART SYS DATA CAM DATA PRESET OK DOME RESTART CONFIRM SAVE DATA DOME RESTART OK SYS DATA CONFIRM FACTORY DEFAULT OK CAM DATA CONFIRM FACTORY DEFAULT OK ...

Page 31: ...pe units grounded in one point Overhead wiring is absolutely prohibited In the strong thunderstorms area or areas with high induced voltage such as high voltage substations measure of installation of additional high power lightning protection equipment and lightning rod must be taken Lightning protection and grounding of outdoor devices and lines must take the lightning protection requirements of ...

Page 32: ...erious user can use a mild detergent Any senior furniture cleaning products can be used to clean the under cover Appendix Ⅲ Common Knowledge on RS 485 Bus 1 Basic Feature of RS 485bus According to industry bus standard of RS 485 RS 485 bus is half duplex communication bus with the characteristic impedance of 120Ω whose maximum load capacity is 32 payloads including the master device and the contro...

Page 33: ...as per the instruction manual Noise after self testing Mechanical obstruction Verify and correct it Camera module is not installed correct Correct Low power Change the correct power supply Image is not stable Low power Check the power supply or make sure the power input is DC 12V Video cable is improperly contact Verify the contact of the video cable Image is blurring Camera is on manual focus Cha...

Page 34: ... Therefore the company reserves the right to modify or improve the products described in this manual without notice The content of manual is offered according to the current state Unless applicable law otherwise specified the company does not make any kind of clear or tacit reassurance about the accuracy reliability and contents of this manual The company reserves the right to revise or recoup thi...

Reviews: