background image

EN

TECHNICAL 

MANUAL

Multi-apartment Gateway 1456B

40-56 Vdc

 

B

+ -

A1

SOLO CON CAVO ROSSO COMELIT 2E7T000500

ONLY WITH COMELIT RED CABLE 2E7T000500

FIXED POE

SETTABLE POE

N0 POE

A2

A3

A4

Art 1456B

Summary of Contents for 1456B

Page 1: ...EN TECHNICAL MANUAL Multi apartment Gateway 1456B 40 56 Vdc B A1 SOLO CON CAVO ROSSO COMELIT 2E7T000500 ONLY WITH COMELIT RED CABLE 2E7T000500 FIXED POE SETTABLE POE N0 POE A2 A3 A4 Art 1456B...

Page 2: ...any purpose other than the intended use failure to observe the indications and warnings contained in this Manual Instruction sheet Comelit Group S p A reserves the right to change the information pro...

Page 3: ...network settings and Restoring factory settings 3 Power supply input via Art 1441 Art 1441B 4 CV1 and CV2 for setting port A2 5 CV3and CV4 for setting port A3 6 A4 non POE Ethernet port for PC or rou...

Page 4: ...rt 1440 via port B there will be sufficient PoE power available to operate a maximum of 1 door as POE on port A1 A2 or A3 Settable POE SETTABLE POE A2 A3 DEFAULT CV1 CV2 CV3 CV4 CV1 CV2 CV3 CV4 NON PO...

Page 5: ...rail mounted Yes DIN modules no 4 Power supply voltage 48Vdc 56Vdc Min max power consumption mA 50mA Operating temperature C 5 C to 40 C Operating relative humidity 25 75 IP protection rating IP30 GEN...

Page 6: ...rsion 2 5 0 or later downloadable from the website pro comelitgroup com An active internet connection is also required f f Article1456B has 2 network interfaces A and B labelled for easy identificatio...

Page 7: ...E NON POE A2 A3 A4 Art 1456B t ROUTER Art 1441 Art 1441B ViP SYSTEM Installer PC with ViP Manager version 2 5 0 and higher with active internet connection INTERNET SIP PROVIDER All system devices form...

Page 8: ...P Manager addressing Follow the procedure below to perform a system scan in DHCP to locate all the devices connected to interfaces A and B an IP address will be automatically assigned to the devices i...

Page 9: ...e 1456 B f select Addressing ViP address g assign an unequivocal ViP address to the device h and press Write page i to save the current settings In the case of a system with 2 1456B devices it will be...

Page 10: ...ing to the same router network e g 192 168 0 1 ASSIGN A NEW STATIC IP ADDRESS TO INTERFACE A The following procedure describes how to assign network settings to the device1456B that are compatible wit...

Page 11: ...ss g assign device 1456B a static IP address h and an IP netmask i compatible with the system for example IP 192 168 0 5 netmask 255 255 255 0 warning the IP address must not already be in use 5 Enabl...

Page 12: ...will be automatically assigned to the devices in addressing mode DHCP connected to interface A if the system is connected to a server with the function active devices with Static IP address will be id...

Page 13: ...ispense with a master internal unit master license An active internet connection is required to complete the license activation procedure A license is needed for each apartment that wishes to make use...

Page 14: ...lit App PSTN GSM Telephone Door entry phone configured as Slave A master door entry monitor is required Up to 15 slaves devices can be added for each apartment including Smartphone Tablet Comelit App...

Page 15: ...n of the Big App application An active internet connection is required to complete the license activation procedure 1 Select article 1456B and select Main Settings DynDNS a 2 Select ComelitDNS b in or...

Page 16: ...router in the navigation bar for example 192 168 1 1 2 Log in by entering the username and password these can be found in the router user manual The port configuration method may differ according to...

Page 17: ...to make telephone calls the user settings and password are to be entered in the SIP phone lines screen 1 Select the device 1456B and select Main Settings SIP settings a 2 Enter the IP address hostname...

Page 18: ...when the line is purchased Some providers also provide a User ID which can be variously designated User authentication user auth or user ID The procedure for phone lines configuration is described be...

Page 19: ...Enabling enable disable the license for the apartment by selecting Enabled Disabled License type assign the type of license purchased for the apartment choosing between Slave Master Telephone ViP add...

Page 20: ...enter the phone number of the device Backup enable disable the backup line to configure the current device as a backup unit to which failed calls to the device specified in the adjacent column Backup...

Page 21: ...f 3 Use the scroll bar g to view all the sections of the directory Intercoms Switchboards CPS Cameras External Units Actuators Lock releases Lock release actions Additional Actuators Complete the requ...

Page 22: ...activation of an actuator Generic actuator Shutter Door Lighting by completing the following fields Description Enter the description ViP address Enter the ViP address Expansion index Select the actua...

Page 23: ...to 10 Output index From the pull down menu select the number of the relay 1 or 2 or the expansion number from 1 to 10 that you wish to control Additional Actuators 11 Message server configuration The...

Page 24: ...n ViP Manager select device 1456B and select Services Remote configuration a 3 Tick Remote connection enable b 4 Enter a password c 5 Press Write page d to save the current settings It will now be pos...

Page 25: ...ess of interface A as specified in the page Addressing IP address Local remote TCP UDP port default 64100 for some internet service providers port 64100 is not available if the ComelitViP Remote App f...

Page 26: ...is also required 1A Enter the registered hostname or the public IP address as in the following examples and press enter With the PC connected via Ethernet cable to interface A of art 1456Ba and IP ad...

Page 27: ...ce in local or remote and log in 2 Access the Backup Restore section by pressing Backup Restore a 3 Press Make Backup b to create a backup of the current configuration A file with the extension tar gz...

Page 28: ...6 At the next restart the device will recover the saved settings Restoring factory settings This procedure allows you to restore all the factory parameter settings and to delete all the device configu...

Page 29: ...nager addressing procedure see 2 ViP Manager addressing 2 Select the device 1456B a 3 Press Add license from the main menu b 4 Press Load from server to restore previously activated licenses c 5 Press...

Page 30: ...24 485 D D 485 P R G D N G S 3360B J2 J1 J2 J1 INTERFACE A IP 192 168 1 X APT 1 PHONE LICENSE APT 2 MASTER LICENSE APT 3 SLAVE LICENSE 192 168 1 1 INTERFACE B AUTO IP RX RX TX TX ORANGE WIRE WHITE OR...

Page 31: ...TX TX RX RX TX TX ORANGE WIRE WHITE ORANGE WIRE WHITE GREEN WIRE GREEN WIRE 1595 120 230 V 33436 100 240 V 4 3 2 1 1456B A B A A A E S NC NO D N G V V M O C 4682HC R T E RX RX TX TX 1595 120 230 V Va...

Page 32: ...for non permanent network devices if there is a limited number of hosts in the subnet and or for security reasons so that the actions of each host and the relative user can be kept under control Publi...