Comelit 1414 Technical Manual Download Page 5

Depending on the type of cable used and the distance between the furthest riser branch internal unit and the mixer, jumper 

JP3 must be arranged according to the settings given in Table 1.

For all other distances refer to:

 

SBTOP audio/video system

.

Jumper JP3 setting for line protection function

Table 1

Max. distance between Mixer 

and furthest internal unit.

Position of jumper JP3

D

Comelit Art. 4577/4579 1 mm² (Ø 1,2 mm AWG 17)

200 m

 (650 feet)

Pos A

1,5 mm² (Ø 1,4 mm AWG 15) 

150 m

 (495 feet)

Pos A

1 mm² (Ø 1,2 mm AWG 17) 

 

120 m

 (390 feet)

Pos A

0,28 mm² (Ø 0,6 mm AWG 23) 

70 m 

(225 feet)

Pos A

100 m

 (325 feet)

Pos B

UTP5 cat. 5 0,2 mm² (Ø 0,5 mm AWG 24) 

50 m

 (160 feet)

Pos A

80 m

 (260 feet)

Pos B

0,5 mm² (Ø 0,8 mm AWG 20)

80 m

 (260 feet)

Pos A

120 m

 (390 feet)

Pos B

  Supplied with Art. 1414

4888C

1414

1214/2C

1216

1214/2C

1216

1214/2C

1216

1214/2C

1214/2C

1216

1414

1414

1414

6700W
6701W
6701B

+6710

6700W/BM
6701W/BM
6701B/BM

6801W
6801W/BM

6601W
6601W/BM

6721W
6721W/BM
+6710

6721W
6721W/BM
+6710

System performance and layouts

For further information of system performance and to view installation layouts, click on the system type that best meets your 

requirements:
• 

Building Kit audio/video system

 for the creation of audio-video systems for 

small apartment blocks.

• 

SBTOP audio/video system

 for the creation of audio-video systems for 

residential complexes.

5