Comelit 1414 Technical Manual Download Page 4

Connection

1414

BUS LINE OUTPUT

BUS LINE INPUT /  4888C / 1210

L

M

L

M

L

OUT

L

OUT

L

IN

L

IN

BRANCH RISER 

OUTPUT

TERMINALS

Operation and Programming

 

f

Jumpers JP1 and JP4 must be removed in order to activate this function.

The line protection function allows the branch line to be automatically isolated in case of short circuit. If this occurs, LED DL1 

lights up to signal the fault (Fig. A). To reinstate the line, after eliminating the problem it is necessary to move jumper JP2 to 

position B until the LED (Fig. B) goes off, then move the jumper to position A (Fig. C).

A

B

C

Line protection function

In Building Kit systems, it is only compatible for the “riser branch” function (not “line protection”).

4

Reviews: