Connection
1414
BUS LINE OUTPUT
BUS LINE INPUT / 4888C / 1210
L
M
L
M
L
OUT
L
OUT
L
IN
L
IN
BRANCH RISER
OUTPUT
TERMINALS
Operation and Programming
f
Jumpers JP1 and JP4 must be removed in order to activate this function.
The line protection function allows the branch line to be automatically isolated in case of short circuit. If this occurs, LED DL1
lights up to signal the fault (Fig. A). To reinstate the line, after eliminating the problem it is necessary to move jumper JP2 to
position B until the LED (Fig. B) goes off, then move the jumper to position A (Fig. C).
A
B
C
Line protection function
In Building Kit systems, it is only compatible for the “riser branch” function (not “line protection”).