27
27
EN
DIP S2
with Art. 6333
DIP 1 DIP 2 DIP 3 DIP 4
P1
P2
A
P3
P4
P5
P6
P7
0
0
0
0
CCS
AI
A
ACT
D
PAN
K
CCP
1
0
0
0
ACT
AI
INT
INTb
D
CCS
PAN
0
1
0
0
INT
AI
INTb
ACT
CCS
CCP
D
1
1
0
0
ACT
CCS
CCP
PAN
K
D
AI
0
0
1
0
ACT
ACT
ACT
ACT
ACT
ACT
ACT
ACT
1
0
1
0
INT
ACT
A
CCS
CCP
INTb
PAN
K
0
1
1
0
AI
D
K
CCS
CCP
INTb
INT
1
1
1
0
INTb
INT
AI
INT
PAN
D
ACT
0
0
0
1
CCS
PAN
D
AI
INT
INTb
CCP
1
0
0
1
K
CCS
PAN
CCP
AI
INT
INTb
0
1
0
1
CCP
K
PAN
ACT
INT
AI
CCS
1
1
0
1
PAN
CCP
CCS
K
ACT
D
AI
0
0
1
1
D
INTb
INT
ACT
AI
CCS
CCP
1
0
1
1
INT
INT
INT
INT
INT
INT
INT
0
1
1
1
NULL
NULL
NULL
NULL
NULL
NULL
NULL
NULL
NULL
1
1
1
1
PROG
Legend
A
Lock- release
CCS
Switchboard call
INTb
Two-family intercom
- for KIT only
Speech
K
Guardian door-entry
phone call
NULL
No function
ACT
Actuator
D
Doctor
PROG
Programmed functions,
see pages 27-32
In this Dip switch setting,
the buttons control the
programmed functions; the
NON-programmed buttons
control functions referred to
on line 0000
AI
Self-ignition
PAN
Panic
CCP
Main switchboard call
INT
Programmable
intercom, general or
selective
-
general internal call
as standard for KIT and
Simplebus Top
DIP S2
with Art. 6333
DIP S1
DIP 1
DIP 2
DIP 3
DIP 4
P1
P2
A
P3
P4
P5
P6
P7
ADDRESS
0
0
0
0
A
ACT
1
0
0
0
ACT
0
1
0
0
ACT
1
1
0
0
ACT
0
0
1
0
ACT
ACT
ACT
ACT
ACT
ACT
ACT
ACT
1
0
1
0
ACT
A
0
1
1
0
1
1
1
0
ACT
0
0
0
1
1
0
0
1
0
1
0
1
ACT
1
1
0
1
ACT
0
0
1
1
ACT
1
0
1
1
0
1
1
1
1
1
1
1
PROG
⇒
LED1
2
LED 2
Default button settings
)FæTHEæDEFAULTæSETTINGSæSEEæTABLEæONæPAGEæ æDOæNOTæREmECTæREQUIREMENTSæ
THEæBUTTONSæCANæBEæPROGRAMMEDæDIFFERENTLYæBYæCARRYINGæOUTæTHEæSTEPSæBELOW
At the end, set S2 DIP switches 1-2-3-4 to the combination 1111
(PROG setting in the configuration tables on pages 27, 28, 29). In this
dip switch setting, the buttons control the programmed functions;
General button programming warnings
the NON-programmed buttons control functions referred to on line
0000 (see table on page 27). Restore the user code setting on S1, see
table A on page 26.
%XAMPLE
ONæAæMONITORæWITHæUSERæCODEææ0æPROGRAMMINGææGENERICæACTUATORæ0ææ
CODEDæACTUATORæCODEæ
æ3ETæ3æ$)0æSWITCHææTOæTHEæCOMBINATIONæ
» LED 1 (red) flashes
æ2EFERæ TOæ THEæ TABLEæ ONæ PAGEæ æ ANDæ SELECTæ Aæ COMBINATIONæ INæ WHICHæ THEæ
ACTUATORæFUNCTIONæ!#4 æISæLISTEDæFORæTHEæBUTTONSæYOUæWISHæTOæPROGRAM
%Gæ FORæ 0æ GENERICæ ACTUATORæ SETæ 3æ $)0æ SWITCHESæ æ TOæ THEæ
Programming buttons for generic or coded actuator
COMBINATIONææORææORææ0!#4 æSETæ3æ$)0æSWITCHESæTOæTHEæ
COMBINATIONææGOæTOæPOINTæ
%Gæ FORæ 0æ CODEDæ ACTUATORæ CODEæ æ SETæ 3æ $)0æ SWITCHESæ æ
TOæTHEæCOMBINATIONææORææ0!#4 æSETæ3æWITHæADDRESSææINæ
ACCORDANCEæWITHæ
table A
æONæPAGEææGOæTOæPOINTæ
æ0RESSæANDæRELEASEæTHEæBUTTONæTOæBEæASSOCIATEDæWITHæTHEæFUNCTION
»LED 2 (blue) flashes 4 times
»confirmation tone
æ4OæEXITæPROGRAMMINGæMODEæSETæ3æ$)0æSWITCHESææTOæTHEæCOMBINATIONæ
00
» LED 1 (red) switches off
5. When programming is complete, set S2 DIP switches 1-2-3-4 to the
combination 1111. Restore the user code setting on S1, see table A
on page 26.
Summary of Contents for 1205/B
Page 114: ...114...