Before starting up
IMPORTANT:
Make sure that the power plug is removed from the socket outlet
before opening the device. Electric shock can cause fatal injury. Have repairs
carried out only by an authorized workshop.
Take the filter out of the unit, take off the plastic sheeting and insert it back in the device.
The main filter should normally be changed every 6-9 months.
To make sure you do not forget, stick the supplied sticker on the outside of the device. This
serves as a color indicator for when to change the filter. When the filter is the same color as
the sticker, it is time to change it.
The white side of the main filter must face towards the front, then you will have inserted it
correctly.
Starting up
Plugging in the device
When you plug in the device, the Power-LED will flash. The device is now ready for use.
Power
•
Press this button to switch the unit on or off.
•
When the device is switched on, the quality sensors will take approx. 2 minutes to
determine the quality of the air. After the air quality has been determined, the device
will show the DUST, VOC polution and the overall air quality.
•
After switching on the device, it will start in manual mode and small fan speed.
•
If you are not intending to use the device for an
extended period of time, we recommend that you pull the power plug.
Timer
•
Use this function to select the start- or runtime for the device.
•
To set the starttime, select the timer when the unit is off.
•
To set the runtime, select the timer when the unit is on.
•
Continuous operation is indicated when all timer LEDs are dark.
•
The remaining time is also shown by the LEDs.
Speed
•
The speed of the fan can be changed during operation by repeatedly pressing this
button to switch between Low, Medium and High.
•
If the unit works in automatic Mode, the fan speed will be regulated automatically.