Comedes BTR 50 Manual Download Page 7

flammable and heavier than 
air. It first collects in low 
areas, but can be circulated 
by fans.

 

 

If propane gas is present, or 

suspected to be present, do 
not allow untrained persons 
to search for the cause.

 

 

The propane gas used in this 
unit is odourless. Therefore, 

gas may have escaped even 
without any perceptible smell.

 

 

The components used are 

designed for propane gas and 
are therefore non-ignitable 
and non-sparking. 
Components may only be 
replaced by identical spare 

parts approved by the 
manufacturer. 

 

Note that the refrigerant is 
odourless. 

 

Compliance with national gas 

regulations must be 
observed.

 

 

 
 

Failure to comply with the safety instructions can lead to explosion, 
death, injury and material damage. 

 
 

 Attention 

Any person carrying out work on the refrigerant circuit shall 
hold a current valid certificate of competence issued by an 

assessment body accredited by the industry which 
demonstrates their competence to safely handle refrigerant in 

accordance with a procedure recognised by the industry.  

 
 
 

    Attention 

Maintenance may only be carried out in accordance with the 

manufacturer's instructions. During maintenance and repairs 
requiring the assistance of other specialists, the person trained 
in handling flammable gases must constantly monitor the 

work. 

 

If you do not understand something or need help, please contact the manufacturer. 
You will find the contact details at the end of this manual.  

 

Appropriate use 

 

The dehumidifier is only intended for dehumidifying privately used rooms (e.g. living rooms, 
bedrooms, storage rooms or cellars). The user must comply with the specified operating para-
meters of this manual. 
The machine may only be used for its intended purpose. Any other use beyond this is not in-
tended. The user/operator and not the manufacturer is liable for any damage or injury of any 
kind resulting from this. 

 

Operating instructions 

 
The device is designed for a temperature range between 5 and 35°C. Below 5°C the air 
humidity tends to be very low, so you do not need to use a dehumidifier. Above 35°C, the 
overheating protection may automatically switch off the unit. The device is not approved for 
operation outside the temperature range. 
The dehumidifier warms the air so that it can dehumidify optimally. Therefore the room 
temperature can rise by 1-2 degrees. This is quite normal and increases the efficiency of the 

Summary of Contents for BTR 50

Page 1: ...Air dehumidifier BTR 50...

Page 2: ...powerful and reliable dehumidifier To ensure that the device will be a faithful servant for a long period of time we ask you to study the operating instructions especially the safety instructions tho...

Page 3: ...ility of the coolant special precautions must be taken Symbols Danger from flammable gas This symbol draws your attention to dangers to health and life caused by extremely flammable gas Observe operat...

Page 4: ...power cord is damaged it must be replaced by the manufacturer its service partner or similarly qualified persons to avoid any risk of danger Please contact a professional to have the product repaired...

Page 5: ...least 20m It must be ensured that there are no flammable materials in the working area of the device Do not clean the dehumidifier with water or chemicals Prevent water from getting on on the applianc...

Page 6: ...rotective contact socket to disconnect the device completely from the mains Do not use naked flames cigarettes or other possible ignition sources inside or near the equipment Transport storage and dis...

Page 7: ...the manufacturer s instructions During maintenance and repairs requiring the assistance of other specialists the person trained in handling flammable gases must constantly monitor the work If you do...

Page 8: ...wer consumption 3 1 A 30 C 80 humidity Dehumidification capacity 51 l day 30 C 80 humidity Weight 36 kg Permissible operating temperature 5 35 C Coolant quantity R290 230g Water tank size 5 5 l Noise...

Page 9: ...completed the current room air humidity is displayed again Assembly Figure 4 Accessories included in delivery 1 air dehumidifier 2 Transport handle 3 Stainless steel screw 4 Spacer washer 5 wheel 6 Sp...

Page 10: ...r at least 24 hours before starting it up for the first time Always operate the appliance in an upright position and do not tilt it during operation Installation Instructions Operate the device only i...

Page 11: ...min 50cm min 50cm min 50cm min 50cm...

Page 12: ...is quite normal and need not worry you Note Before using the device for the first time we recommend that you operate it for 5 10 minutes with the window open to remove any production related residues...

Page 13: ...old the Timer button for at least 3 seconds and the current room temperature is shown on the display After approx 10 seconds the current room humidity is displayed again Empty water tank When the wate...

Page 14: ...it completely 2 Pull the plug from the hose connection of the water tank and insert it back into the appliance 3 Insert a suitable drainage hose from the outside through the opening provided in the h...

Page 15: ...manual can only give limited help we recommend that you find more information at www comedes com Basics for dehumidification with the Comedes BTR 50 The dehumidifier works similar to a refrigerator w...

Page 16: ...th condensation dryers such as the BTR 50 The dehumidifier is operated in continuous operation The ambient temperature should be at least 20 C no more than 27 C Caution Only heat the room with water b...

Page 17: ...The diagram assumes that temperatures 20 C are living rooms and temperatures 20 C are basement rooms Maintenance...

Page 18: ...if neces sary Check device for damage power cable housing tank fan wheel Check fastening screws Trial run Empty tank or check hose drai nage Visual inspection of the sockets used Testing of the RCD g...

Page 19: ...logged or damaged replace it with a new one Storage of the dehumidifier If the dehumidifier is not used for a longer period of time 1 Switch on and disconnect the device 2 Empty the water tank complet...

Page 20: ...humidity too low The unit does not switch off in automatic mode 1 are the windows and doors closed 2 does a device produce steam in this room 3 Is the room too big The device is very loud 1 is the du...

Page 21: ...cord or plug becomes disproportionately warm Stop the operation and contact us at service comedes com There are objects or water in the device Stop operating and contact us at service comedes com Atte...