Comedes BTR 50 Manual Download Page 10

 

Soft underlay (blanket, sleeping mat, towel or similar) 

 
 

Assembly steps for the BTR 50: 

 

 
 
Attention 

Please note that the device is heavy. To avoid injuries or damage to the device 
and objects in the vicinity, the installation should be carried out by 2 persons.  

 
A)

 

Preparation 

a.

 

Remove the dehumidifier from the packaging and check it for damage 

b.

 

Check the accessories (mounting set) for completeness. 

c.

 

Prepare the tools required for the assembly. 
 

B)

 

Mounting (See Figure 4) 

a.

 

Carefully place the device on its front side. Lay a soft surface (blanket, mattress, 
towel, etc.) underneath to avoid damage such as scratches. 

b.

 

Assemble the transport handle using the 4 stainless steel screws, as shown in Figure 
4. 

c.

 

Mount the two wheels as shown in Figure 4. 

d.

 

Now carefully place the device on its back. Lay a soft surface (blanket, mattress, 
towel, etc.) underneath to avoid damage such as scratches. 

e.

 

Mount the stand as shown in Figure 4. 

f.

 

Return the dehumidifier to an upright position. 

 

Leave the appliance in its final, upright position for at least 24 hours before starting 
it up for the first time. 
Always operate the appliance in an upright position and do not tilt it during 
operation. 

 
 

Installation Instructions 

 

Operate the device only in rooms with at least 20m². 
floor space 

 

 

Remove all adhesive tapes that were used for transport securing. 

 

Check that the device is standing securely on firm, level and dry ground. 

 

Never install the unit where it may be exposed to the following conditions: 

o

 

Heat sources, such as radiators, heat registers, stoves or other products that 
generate heat 

o

 

In an area where oil or water can be splashed. 

o

 

Direct solar radiation 

o

 

Mechanical vibrations or shocks 

o

 

Excessive dust exposure 

o

 

Lack of ventilation, e.g. in a cupboard or bookshelf 

o

 

Uneven surface 

 
 

 

Make sure that the power outlet is equipped with an RCD (ground fault circuit interrupter). 

If you are not sure whether this is the case, you can ask your electrician or use 
a personal protection plug (available at a hardware store). 
 

 

 

To save power and avoid potential hazards, disconnect the unit when not in use. 
 

 

Keep at least 50cm distance around the device to walls and objects. Make sure that the air 

outlet is free and that there are no curtains or textiles above it. 

 

Summary of Contents for BTR 50

Page 1: ...Air dehumidifier BTR 50...

Page 2: ...powerful and reliable dehumidifier To ensure that the device will be a faithful servant for a long period of time we ask you to study the operating instructions especially the safety instructions tho...

Page 3: ...ility of the coolant special precautions must be taken Symbols Danger from flammable gas This symbol draws your attention to dangers to health and life caused by extremely flammable gas Observe operat...

Page 4: ...power cord is damaged it must be replaced by the manufacturer its service partner or similarly qualified persons to avoid any risk of danger Please contact a professional to have the product repaired...

Page 5: ...least 20m It must be ensured that there are no flammable materials in the working area of the device Do not clean the dehumidifier with water or chemicals Prevent water from getting on on the applianc...

Page 6: ...rotective contact socket to disconnect the device completely from the mains Do not use naked flames cigarettes or other possible ignition sources inside or near the equipment Transport storage and dis...

Page 7: ...the manufacturer s instructions During maintenance and repairs requiring the assistance of other specialists the person trained in handling flammable gases must constantly monitor the work If you do...

Page 8: ...wer consumption 3 1 A 30 C 80 humidity Dehumidification capacity 51 l day 30 C 80 humidity Weight 36 kg Permissible operating temperature 5 35 C Coolant quantity R290 230g Water tank size 5 5 l Noise...

Page 9: ...completed the current room air humidity is displayed again Assembly Figure 4 Accessories included in delivery 1 air dehumidifier 2 Transport handle 3 Stainless steel screw 4 Spacer washer 5 wheel 6 Sp...

Page 10: ...r at least 24 hours before starting it up for the first time Always operate the appliance in an upright position and do not tilt it during operation Installation Instructions Operate the device only i...

Page 11: ...min 50cm min 50cm min 50cm min 50cm...

Page 12: ...is quite normal and need not worry you Note Before using the device for the first time we recommend that you operate it for 5 10 minutes with the window open to remove any production related residues...

Page 13: ...old the Timer button for at least 3 seconds and the current room temperature is shown on the display After approx 10 seconds the current room humidity is displayed again Empty water tank When the wate...

Page 14: ...it completely 2 Pull the plug from the hose connection of the water tank and insert it back into the appliance 3 Insert a suitable drainage hose from the outside through the opening provided in the h...

Page 15: ...manual can only give limited help we recommend that you find more information at www comedes com Basics for dehumidification with the Comedes BTR 50 The dehumidifier works similar to a refrigerator w...

Page 16: ...th condensation dryers such as the BTR 50 The dehumidifier is operated in continuous operation The ambient temperature should be at least 20 C no more than 27 C Caution Only heat the room with water b...

Page 17: ...The diagram assumes that temperatures 20 C are living rooms and temperatures 20 C are basement rooms Maintenance...

Page 18: ...if neces sary Check device for damage power cable housing tank fan wheel Check fastening screws Trial run Empty tank or check hose drai nage Visual inspection of the sockets used Testing of the RCD g...

Page 19: ...logged or damaged replace it with a new one Storage of the dehumidifier If the dehumidifier is not used for a longer period of time 1 Switch on and disconnect the device 2 Empty the water tank complet...

Page 20: ...humidity too low The unit does not switch off in automatic mode 1 are the windows and doors closed 2 does a device produce steam in this room 3 Is the room too big The device is very loud 1 is the du...

Page 21: ...cord or plug becomes disproportionately warm Stop the operation and contact us at service comedes com There are objects or water in the device Stop operating and contact us at service comedes com Atte...

Reviews: