MicroBlaster MB1005
Section 5: Trouble-Shooting and Repair
Comco Inc.
5-7
Issue Date: September 2003
Abrasive Hose Replacement Procedure
(cont’d)
7.
Feed a 6 ft. length of new hose MB1233 (or the old cut back hose)
through the pinch tube.
8.
Slip the rubber grommet (ST5010) and the Quicknut onto the hose.
9.
Work the end of the hose onto the hose connector fitting, and tighten the
Quicknut onto the connector. Hand tighten only.
Hose Connector Fittings
When installing replacement fittings that have pipe threads, use a small amount of
thread sealing compound or tape to insure leak free joints.
CAUTION
: Using improper fittings, or fittings that have
been improperly installed or assembled, can
present a hazard.
Hose Connector Replacement Procedure (MB1455)
1.
Turn the Power OFF.
2.
At the rear panel of the MicroBlaster, cut the hose approximately 3" from
connector.
3.
Using a 7/16" open-end wrench, remove the old hose connector.
4.
Remove the blue Quicknut from the new hose connector and attach the
connector to the rear of the unit. Tighten with a 7/16" open-end wrench.
5.
Slide the Quicknut onto the hose and work the end of the hose onto the
new connector. Tighten the Quicknut onto connector. Hand tighten only
Summary of Contents for MB1005-1
Page 10: ......