Air Pressure Regulator Assembly
The Air Pressure regulator adjusts the source air pressure down to a useful blasting pressure as
indicated by the gage. The regulator assembly contains the regulator, check valve, filter and
hose fittings. Refer to Appendix B, Figure 11.
Indications of a regulator failure:
a)
Gage goes to “Max” at idle but drops drastically when blasting.
b)
Regulator knob will not turn in either direction.
c)
Regulator knob turns freely, but never tops or bottoms out (no high or low
stop).
Replace the Regulator Assembly according to the following procedure:
Air Pressure Regulator Assembly Replacement Procedure
1.
Turn Power OFF and depressurize unit.
2.
Remove the DirectFlo cover (4 screws).
3.
Disconnect the hoses from the regulator assembly. You may want to
label each air hose before removing.
4.
Remove the retaining nut from the front of the regulator.
5.
Remove the cap from the knob by squeezing the sides of the cap and pop
it off (similar to removing a child-proof cap from a pill bottle). You will
need to do the same with the new regulator.
6.
Pull the regulator assembly back into chassis and remove.
7.
Install the new regulator (PF2443).
8.
Attach the air hoses to the regulator assembly.
9.
Install the cover.