background image

GAS-HEATED CHARCOAL-GRILL

Mod. 

A

GL7-4G

Mod. 

A

GL7-8G

Serie 70

INSTRUCTIONS FOR INSTALLATION, ADJUSTMENT, USE AND MAINTENANCE  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 2-4

APPENDIX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pagina 5-6

Read the manual thoroughly
and keep it in a safe place
throughout the product's
service life.
Read the warning notes
immediately!

DOC. NO. 

CR0500420

0

5

01

Summary of Contents for AGL7-4G

Page 1: ...G Serie 70 INSTRUCTIONS FOR INSTALLATION ADJUSTMENT USE AND MAINTENANCE page 2 4 APPENDIX pagina 5 6 Read the manual thoroughly and keep it in a safe place throughout the product s service life Read the warning notes immediately DOC NO CR0500420 0501 ...

Page 2: ...ING PROCEDURE 3 Testing the gas system Testing the nominal thermal power Setting the manifold gas pressure TROUBLESHOOTING GUIDE 3 The pilot burner is difficult or impossible to ignite The pilot burner goes out during use The main burner is difficult or impossible to ignite REPLACEMENT OF SPARE PARTS 3 Burners Thermocouples Ignition electrodes Gas tap Piezo igniter USE AND MAINTENANCE INSTRUCTIONS...

Page 3: ...upply Install a shut off valve upstream of the appliance in a place easily accessible Check if the appliance is adjusted for the type of gas with which it will be supplied If not convert it according to the instructions in the paragraph Conversion to different type of gas Check that there are no leaks at the connection points CONVERSION TO A DIFFERENT TYPE OF GAS To convert the appliance to a diff...

Page 4: ...ised service centres For service and spares parts please contact Comcater 1800 810 161 The manufacture declines any responsibility if these obligations are not respected Read this manual carefully and keep in a safe place Before using the appliance thoroughly clean all surfaces that may come into contact with food USE Lava stone The appliance is supplied with 2 packs of lava stone per brazier Spre...

Page 5: ...L GAS PROPANE NATURAL GAS PROPANE NATURAL GAS PROPANE Appendix 40 25 2 25 2 T1 INJIECTOR OREFICES SIZES CR0500420 5 6 MM 40 MJ h 1 13 2 75 kPa MM A MM MARKING T2 BURNER AERATION SHUTTERS SETTING T3 NOMINAL GAS CONSUMPTION T4 MAXIMUM GAS INLET PRESSURE 1 00 2 60 T5 NOMINAL TEST POINT PRESSURE VALUES VALUES SHOWN ARE THOSE MEASURED AT THE MANIFOLD PRESSURE TEST POINT kPa ...

Page 6: ...APPENDICE ANHANG APPENDIX APPENDICE APÉNDICE AANHANGSEL SERIE 70 Mod AGL7 4G AGL7 8G INSTALLATION DIAGRAM Measurements in cm Key G Gas connection ISO 7 1 R3 4 CR0500420 6 6 ...