6
www.combisteel.com
Table 2 – Set of delivery: cold rom of capacity of ____________ m3.
Nomenclature
Quantity,
numbers,
(m, kg)
Nomenclature
Quantity,
numbers,
(m, kg)
Operations Manual
1
Junction box
1
Floor panels
2-section terminal element
1
Ceiling panels
*
Cable fixing clamp with elements:
self-tapping screw 4.2x16
4
8
Side panels
*
Partitions
*
Door frame
1
Posts
4
Wire PVC 2х0.75
*
Door
1
Isolan packer, m
*
Door hinge
with fixing elements:
screw М6х20
plug
2
16
16
White silicon sealant
(1nos/10m
3
)
Door handle with lock
(disassembled) with fixing elements:
screw М6х75
screw М6х20
1
2
2
Grey plastic sealant (kg)
0.5
Angle piece 36х36х400
self-tapping screw 4.2x16
(4 nos. per 1 angle piece))
*
*
Threshold strap with
fixing elements:
self-tapping screw 4.2x16
self-tapping screw 4.2x25
1
5
5
Plug 6
10
Fixing elements for box and
terminator space
шуруп 3х30
3
Plug 4
1
* - to be entered depending upon the cold room volume
2.2. Manufacturer’s warranty
The manufacturer warrants that the cold room meets the requirements of specifications ТУ 107-2007 ИТВН
695111.000 «Heat-Insulated Cold Rooms. Specifications» provided that the terms and rules of transportation,
storage, installation, operation stipulated in the Operations Manual are observed.
The warranty service life of a cold room is 12 months since the date of operation commenced, but not more than
18 months since the date of production. The warranty storage life of a cold room is 6 months since the date of
production. The warranty is valid when the below listed documents are available:
Operations Manual;
Operation Commencement Statement;
Technical Statement;
Maintenance Contracts concluded with a specialized body.
The warranty is recalled if:
some rules of transportation, storage, assembly and operation specified in the Operations Manual were
violated in part or in full;
the startup operations or the scheduled maintenance were performed by a body that had no proper
authorization to do so;
the product design was revised without a written consent of the manufacturer.