![CombiSteel 7450.0005 User Manual Download Page 5](http://html1.mh-extra.com/html/combisteel/7450-0005/7450-0005_user-manual_2639342005.webp)
5
Thermostat
The thermostat is placed in the control panel, see fig. 2.0.
Fig. 2.0
The thermostat has been pre-set and in most cases it is not necessary to adjust the settings.
When turning on the counter top the display will show the current temperature in the counter top.
Display set temperature:
Press this key and the display will show the set temperature. Press the key again to return to normal
reading
Set new temperature:
Press this key continuously for more than 3 seconds and the display shows the set temperature.
Press this key to increase the set temperature.
Press this key to lower the set temperature.
Press this key to save the new settings. The display will flash with the new value and will then return
to normal reading.
Alarm codes:
‘P1’
Flashing in the display: indicates that the counter top sensor is defective.
The counter top will strive to keep the set temperature until it has been repaired.
Maintenance and cleaning
Switch the cooler off at the socket.
The counter top must be periodically cleaned. Clean the external and internal surfaces of the counter top with a
light soap solution and subsequently wipe dry. External surfaces can be maintained using steel oil.
Do NOT use cleansers containing chlorine or other harsh cleansers, as these can damage the stainless steel
surfaces and the internal cooling system.
Clean the condenser and the compressor compartment using a vacuum cleaner and a stiff brush.
Do NOT hose the compressor compartment with water as this can cause short circuits and damage on the
electrical parts.