15
www.combisteel.com
Remote Control Sensor:
•
Remote control sensor receives infrared (IR) signal from the remote control. The maximum distance for
IR data transmission is 3 meter (10 ft.) and requires direct line of sight. The transmission distance may
vary depending on temperature and remote control battery condition.
Note: Light settings are independent from other settings (including power-off delay) and lights have to be
manually turned on or off.
USE AND CARE
Troubleshooting
If the range hood or halogen light does not
operate after installation:
Check if the range hood has been plugged in, make
sure that all power has been turned back ON, fused
not blown and all electrical wiring are properly
connected.
Swap out light assembly to working ones to
determine whether it is caused by defective bulbs.
See Replacing the light bulbs on Page 21/22.
The range hood vibrates when the blower is on:
The range hood might not have
The blower or fan seems weak:
Check that the duct sized used is at least 8” or 3-1/4
x 10”. Range hood WILL NOT function efficiently with
insufficient duct size. For example: 10” duct over 8”
hole and loosely secured.
Check if duct is clogged or if damper unit (half-
circular flapper) is not installed correctly or opening
properly. A tight mesh on a side wall cap unit might
also cause restriction to the air flow.
The lights work but the blower is not spinning
at all, is stuck or is rattling.
•
The blower might be jammed or scraping the bottom
•
due to shipping damage. Please contact us
immediately.
The hood is not venting out properly:
•
Make sure the distance between the stove top and
the bottom of the hood is within* 27” and 30” in
distance. *Due to different ceiling height
configurations, recommended height may not be
applicable.
•
Reduce the number of elbows and length of duct
work. Check if all joints are properly connected,
sealed, and taped.
•
Make sure the power is on high speed for heavy
cooking.
Summary of Contents for 7227.0005
Page 6: ...6 www combisteel com INSTALLATION Tools needed Parts supplied...
Page 18: ...18 www combisteel com Hood mounting Bracket Circuit Diagram...
Page 27: ...27 www combisteel com INSTALLATIE Benodigd gereedschap Meegeleverde onderdelen...
Page 39: ...39 www combisteel com Montagebeugel afzuigkap Circuit diagram...
Page 48: ...48 www combisteel com INSTALLATION Ben tigte Werkzeuge Gelieferte Teile...
Page 60: ...60 www combisteel com Haubenbefestigungshalterung Schaltkreisdiagramm...
Page 69: ...69 www combisteel com INSTALLATION Outils n cessaires Pi ces fournies...
Page 81: ...81 www combisteel com Support de capot Diagramme de circuit...
Page 88: ...88 www combisteel com...