2.5.2 OPERATION & MAINTENANCE
Local Monitoring Feature
PC via RS232
Remote Data Transfer
Integrated wireless modem (data or SMS), OMC
(optional)
Local and Remote Controlled Parameters
Channel No., ATT, PW On/Off, Oscillation On/Off, Over-
Temp Threshold, UL/DL Output Power Low Threshold,
DL Input Power Low Threshold, Alarm Report Enable
Local and Remote Monitored Parameters
Alarms (LNA, PA, PLL unlock, Power Down, Power
Fault, Chassis Lock, Self oscillation, DL Input Power
Low, Over Temp, UL/DL Output Power Low), UL/DL
Output Power, DL Input Power
Table 5: Management of RD-9120