Setpoint group
RPMdep Protect
Related FW
3.0.0
Range [units]
0,0 .. 10,0 [Bar]
Default value
0,0
YES
Step
0,1
Comm object
10145
Related applications
PRP
Config level
Standard
Setpoint visibility
Always
Description
Linear Warning characteristic is defined by two points for
Idle RPM
and
Nominal RPM
.
CPNomRPMWr
n
defines coolant pressure warning level at nominal speed. For details see
description.
CPNomRPMWrn
Setpoint group
RPMdep Protect
Related FW
3.0.0
Range [units]
0,0 .. 10,0 [Bar]
Default value
0,0
Step
0,1
Comm object
10146
Related applications
PRP
Config level
Standard
Setpoint visibility
Always
Description
Linear Shutdown characteristic is defined by two points for
Idle RPM
and
Nominal RPM
.
CPIdleRPMSd
defines coolant pressure shutdown level at idle speed. For details see
description.
CPIdleRPMSd
Setpoint group
RPMdep Protect
Related FW
3.0.0
Range [units]
0,0 .. 10,0 [Bar]
Default value
0,0
Step
0,1
Comm object
10147
Related applications
PRP
Config level
Standard
Setpoint visibility
Always
Description
Linear Shutdown characteristic is defined by two points for
Idle RPM
and
Nominal RPM
.CPNomRPMSd
defines coolant pressure shutdown level at nominal speed. For details see
description.
CPNomRPMSd
Summary of Contents for InteliDrive DCU Marine
Page 29: ...InteliDrive DCU Marine 3 0 0 Global Guide 29 Protection delay and blocking ...
Page 51: ...InteliDrive DCU Marine 3 0 0 Global Guide 51 4 2 2 Electronic engine without redundancy line ...
Page 255: ...InteliDrive DCU Marine 3 0 0 Global Guide 255 Analog inputs from J1939 configuration ...
Page 265: ...InteliDrive DCU Marine 3 0 0 Global Guide 265 Engine Values ...
Page 285: ...InteliDrive DCU Marine 3 0 0 Global Guide 285 6 back to Appendix 6 back to Table of contents ...