InteliDrive DCU Marine - 3.0.0 Global Guide
145
Setpoint group
RPMdep Protect
Related FW
3.0.0
Range [units]
0,0 .. 10,0 [Bar]
Default value
0,0
Step
0,1
Comm object
10141
Related applications
PRP
Config level
Standard
Setpoint visibility
Always
Description
Linear Warning characteristic is defined by two points for
Idle RPM
and
Nominal RPM
.OPNomRPMWrn
defines oil pressure warning level at nominal speed. For details see
OilPrRPMdel
description.
OPNomRPMWrn
Setpoint group
RPMdep Protect
Related FW
3.0.0
Range [units]
0,0 .. 10,0 [Bar]
Default value
0,0
Step
0,1
Comm object
10142
Related applications
PRP
Config level
Standard
Setpoint visibility
Always
Description
Linear Shutdown characteristic is defined by two points for
Idle RPM
and
Nominal RPM
.
OPIdleRPMSd
defines oil pressure shutdown level at idle speed. For details see
description.
OPIdleRPMSd
Setpoint group
RPMdep Protect
Related FW
3.0.0
Range [units]
0,0 .. 10,0 [Bar]
Default value
0,0
YES
Step
0,1
Comm object
10143
Related applications
PRP
Config level
Standard
Setpoint visibility
Always
Description
Linear Shutdown characteristic is defined by two points for
Idle RPM
and
Nominal RPM
.OPNomRPMSd
defines oil pressure shutdown level at nominal speed. For details see
description.
OPNomRPMSd
Summary of Contents for InteliDrive DCU Marine
Page 29: ...InteliDrive DCU Marine 3 0 0 Global Guide 29 Protection delay and blocking ...
Page 51: ...InteliDrive DCU Marine 3 0 0 Global Guide 51 4 2 2 Electronic engine without redundancy line ...
Page 255: ...InteliDrive DCU Marine 3 0 0 Global Guide 255 Analog inputs from J1939 configuration ...
Page 265: ...InteliDrive DCU Marine 3 0 0 Global Guide 265 Engine Values ...
Page 285: ...InteliDrive DCU Marine 3 0 0 Global Guide 285 6 back to Appendix 6 back to Table of contents ...