Page 14 of 16
INSTRUCTION MANUAL
LI-125C
LINE IMPEDANCE STABILIZATION NETWORK
19121 El T oro R d ● S il vera d o, Ca lifo rnia 926 76 ● (94 9) 459 - 9600 ● com - p ower.com
REV011617
7.0 T
YPICAL
P
ERFORMANCE
D
ATA
Figure 6: Typical Impedance compared to ANSI C63.5 & CISPR 16-1-2 requirements
Figure 7: Typical Phase compared to CISPR 16-1-2 requirements.
20
30
40
50
60
70
0.1
1
10
100
Imp
ed
ance
(ohms)
Frequency (MHz)
LISN Impedance
CISPR 16-1-2,
Ed.1.2, Tbl 4
(50uH)
Impedance
Limits (±20%)
ANSI C63.4-
2009, Tbl B.2
(50uH)
Impedance
Limits (±20%)
-20
-10
0
10
20
30
40
50
60
70
0.1
1
10
100
Ph
ase
A
ngle
(d
eg
ree
s)
Frequency (MHz)
LISN Phase
CISPR 16-1-2,
Ed.1.2, Tbl 4
(50uH) Phase
Limits (±11.5°)
Distributed by: Reliant EMC LLC, +1 408 916
‐
5750, [email protected], www.reliantemc.com