3.4.2 

Description of FCLC-100 Calibration Fixture Features 

 
 
 
 
 
 
 
 
 
 

FIGURE 2  - 

 

FCLC-100 Calibration Fixture  Features 

Fixture Opening 

1

 

The CLCI-100 is installed within this opening so that the center conductor rod of the fixture 
passes through the approximate center of the probe aperture.  

Center Conductor Rod 

2

 

This is the fixture’s center conductor. 

Calibration Fixture Coaxial Ports 

3

 

These are female N-type coaxial connectors providing input/output connections to the 
fixture. 

Thumb Screws for Removable Top Plate 

4

 

These (6) screws secure the fixture’s top plate to the fixture assembly.   

Removable Top Plate of Fixture 

5

 

In order to install/remove the clamp into/from the calibration fixture, the top plate must be 

removed by removing the six (6) thumb screws.  The top cover and thumb screws must be 
replaced prior to the performance of tests. 

 

 

 

 

 

 

 

 

 

 

 

2

3

4

1

3

5

FCLC-100

www.com-power.com

4

4

4

4

4

3

3

All manuals and user guides at all-guides.com

Summary of Contents for CLCI-100

Page 1: ...ALIBRATION FIXTURE 19121 El Toro Rd Silverado California 92676 949 459 9600 com power com REV051917 INSTRUCTION MANUAL For BULK CURRENT INJECTION PROBE Model CLCI 100 and CALIBRATION FIXTURE Model FCL...

Page 2: ...cations for FCLC 100 Calibration Fixture 10 3 6 Product Dimensional Diagrams 11 3 6 1 Dimensions of CLCI 100 Bulk Current Injection Probe 11 3 6 2 Dimensions of FCLC 100 Calibration Fixture 12 4 0 Usi...

Page 3: ...I 100 Probe into FCLC Calibration Fixture 13 FIGURE 6 Setup for Insertion Coupling Loss in a 50 System 100 Loop 14 FIGURE 7 Setup for Insertion Coupling Loss in a 150 System 300 Loop 14 FIGURE 8 Equiv...

Page 4: ...100 Bulk Current Injection Probe connections product specifications safety precautions operational instructions calibration instructions measurement guidelines and warranty information Information co...

Page 5: ...DN Comb Generators Current Probes Emissions Test Systems Conducted Immunity Test Systems Impedance Stabilization Networks ISN Line Impedance Stabilization Networks LISN Antenna Masts Near Field Probe...

Page 6: ...m Power or your Com Power distributor Please check the contents of the shipment against the package inventory in section 3 2 to ensure that you have received all applicable items 3 2 Package Inventory...

Page 7: ...structions WATER AND MOISTURE Do not use the instrument near water WALL OR CEILING MOUNTING Do not mount the instrument on a wall or ceiling HEAT The instrument should be situated away from heat sourc...

Page 8: ...nector Spring loaded Clasps 2 These two 2 clasps when secured over their respective brackets lock the clamp into its closed position Clasp Brackets 3 These two 2 brackets anchor the respective clasp b...

Page 9: ...erture Center Conductor Rod 2 This is the fixture s center conductor Calibration Fixture Coaxial Ports 3 These are female N type coaxial connectors providing input output connections to the fixture Th...

Page 10: ...4 7 cm Probe Aperture Diameter 1 575 4 cm Weight 4 5 lbs 2 04 kg Environmental Operating Temperature 40 F to 104 F 5 C to 40 C 3 5 2 Specifications for FCLC 100 Calibration Fixture Technical Product C...

Page 11: ...CI 100 Bulk Current Injection Probe FIGURE 3 Dimensional Diagram for CLCI 100 Bulk Current Injection Probe CLCI 100 Bulk Current Injection Probe 10 kHz to 100 MHz Max Input 100 Watts CW www com power...

Page 12: ...verado California 92676 949 459 9600 com power com REV051917 3 6 2 Dimensions of FCLC 100 Calibration Fixture FIGURE 4 Dimensional Diagram for FCLC 100 Calibration Fixture SIDE VIEW TOP VIEW W 7 17 8...

Page 13: ...The intent of the fixture is to maintain the coaxial structure of the transmission line while allowing the probe to be installed around the center conductor of the coaxial line 4 1 Installation of CLC...

Page 14: ...present during operation Do not handle probe while test is in progress GROUND PLANE 10 dB 10 dB NORMALIZATION CALIBRATION 50 SYSTEM 100 LOOP OUTPUT RF Network Analyzer with S Parameter Capabilities o...

Page 15: ...the equivalent calibration circuit along with the associated calculations FIGURE 8 Equivalent Schematic of Calibration Circuit 50 V1 IP CLCI 100 Bulk Current Injection Probe 10 kHz to 100 MHz Max Inp...

Page 16: ...reproduced during the actual testing process For the purposes of this procedure we will refer to these as METHOD A Signal Generator Output Method and METHOD B Forward Power Method Illustrated in Figur...

Page 17: ...ion process the forward power of the test generator is recorded The forward power is measured with an RF power meter and power sensor typically connected to the forward port of a directional coupler i...

Page 18: ...cuit test level Uo for the calibration i e 1 Vrms 3 Vrms 10 Vrms etc The relationship between Umr and Uo is given below So for instance if calibration is being performed for a test level of 10 Vrms Du...

Page 19: ...tcal signal generator output determined during calibration at highest test level FWDpwrcalc calculated forward power for lower test level FWDpwrcal forward power measured during calibration at highest...

Page 20: ...ut 100 Watts CW www com power com CAUTION Hazardous voltages present during operation Do not handle probe while test is in progress CLCI 100 Bulk Current Injection Probe 10 10 kH kHz t to 10 100 M 0 M...

Page 21: ...CLCI 100 Bulk Current Injection Probe 10 kHz to 100 MHz Max Input 100 Watts CW www com power com CAUTION Hazardous voltages present during operation Do not handle probe while test is in progress CLCI...

Page 22: ...ion 4 4 2 1 3 Record either a the frequency fx and amplitude setting of the signal generator SGout or b the frequency fx and forward power measured using the power meter sensor FWDpwr See examples of...

Page 23: ...he present test frequency or b the level at which the power indicated by the power meter is equal to the respective FWDpwr value determined during calibration for the present test frequency 3 Record t...

Page 24: ...t is performed from the lowest test frequency to the highest test frequency one test frequency at a time with a one to three second dwell time at each test frequency The RF carrier is typically 80 amp...

Page 25: ...ECEIVER INPUT EQUIPMENT UNDER TEST EUT AUXILIARY EQUIPMENT AE CLCI 100 Bulk Current Injection Probe 10 kHz to 100 MHz Max Input 100 Watts CW www com power com CAUTION Hazardous voltages present during...

Page 26: ...e 10 kHz to 100 MHz Max Input 100 Watts CW www com power com CAUTION Hazardous voltages present during operation Do not handle probe while test is in progress FRONT VIEW www com power com FCLC 100 CLC...

Page 27: ...to repair damage resulting from attempts to install repair service or modify the instrument by personnel other than Com Power service representatives Under no circumstances does Com Power recognize o...

Page 28: ...00 com power com REV051917 6 0 Typical CLCI 100 Calibration Data Typical Insertion Loss Values Transfer Impedance Factors Meter Reading dBuV Transfer Impedance Factor dB Current Reading dBuA 0 5 10 15...

Reviews: