Page 10 of 28
INSTRUCTION MANUAL
CLCI-100
BULK CURRENT INJECTION PROBE
with
FCLC-100
CALIBRATION FIXTURE
1912 1 E l T o ro R d
●
Si l vera do, Ca lifo rni a 9 26 76
●
(9 49) 459 -96 00
●
co m-p o wer. com
REV051917
3.5
Product Specifications
3.5.1
Specifications for CLCI-100 Bulk Current Injection Probe
Technical
Product
Bulk Current Injection Probe
Model
CLCI-100
Frequency Range
10 kHz to 100 MHz
Standard(s)
IEC 61000-4-6, MIL-STD 461x, RTCA-DO-160x, etc
Impedance
50
Ω
(nominal)
Transfer Impedance Factors see graph(s) located in Section 6
Maximum Input Power
100 Watts
(continuous)
Mechanical
Coaxial RF Connector
N-type
(female)
Dimensions (H)x(W)x(L)
5” x 2.75” x 5.78”
(12.75 x 7 x 14.7 cm)
Probe Aperture Diameter
1.575”
(4 cm)
Weight
4.5 lbs
(2.04 kg)
Environmental
Operating Temperature
40°F to 104°F
(5°C to 40°C)
3.5.2
Specifications for FCLC-100 Calibration Fixture
Technical
Product
Calibration Fixture
Model
FCLC-100
Frequency Range
10 kHz to 100 MHz
Standard(s)
IEC 61000-4-6, MIL-STD 461x, RTCA-DO-160x, etc
Impedance
50
Ω
(nominal)
0.01-2.5 MHz
≤
1.01 : 1
2.5-10 MHz
≤
1.04 : 1
10-30 MHz
≤
1.1 : 1
VSWR
(empty fixture –
no probe installed)
30-100 MHz
≤
1.4 : 1
Mechanical
Coaxial RF Connectors
(2) N-type
(female)
Dimensions (H)x(W)x(L)
6.4” x 7” x 10”
(16.3 x 17.8 x 25.5 cm)
Weight (empty fixture)
8 lbs.
(3.63 kg)
Dimensional Accommodations for Current Probes
Max. Probe Diameter
5.63”
(14.3 cm)
Min. Probe Aperture Diameter
0.79”
(2 cm)
Max. Probe Width
2.83”
(7.2 cm)
Environmental
Operating Temperature
40°F to 104°F
(5°C to 40°C)