background image

 

Page 12 of 18

 

INSTRUCTION MANUAL

 

 

SECTI ON   3    

-

   

PRODUC T I NFORMATION  

 

 

Rev090519 

 

Summary of Contents for CLCE-452

Page 1: ...Page 1 of 18 INSTRUCTION MANUAL Rev090519 INSTRUCTION MANUAL for RF CURRENT PROBE Model CLCE 452 and CALIBRATION FIXTURE Model FCLCE 452 optional...

Page 2: ...Page 2 of 18 INSTRUCTION MANUAL TABLES OF CONTENTS Rev090519...

Page 3: ...Page 3 of 18 INSTRUCTION MANUAL TABLES OF CONTENTS Rev090519...

Page 4: ...rstanding of the current relevant standards at the time that this manual was written However the information may become dated or may be inappropriate for some applications The user is cautioned to ref...

Page 5: ...Page 5 of 18 INSTRUCTION MANUAL SECTION 2 PRODUCTS AVAILABLE FROM COM POWER Rev090519...

Page 6: ...e package contents are not complete contact Com Power or your Com Power distributor Please check the contents of the shipment against the package inventory in section 3 2 to ensure that you have recei...

Page 7: ...away from heat sources such as heat registers or other instruments which produce heat CLEANING Clean the instrument outside surfaces of the device with a soft lint free cloth If necessary a mild dete...

Page 8: ...ed Clasps These two 2 clasps when secured over their respective brackets lock the clamp into its closed position Clasp Brackets These two 2 brackets anchor the respective clasps in order to lock the c...

Page 9: ...nectors providing input output connections to the fixture Thumb Screws for Removable Top Plate These 4 screws secure the fixture s top plate to the fixture assembly Removable Top Plate of Fixture In o...

Page 10: ...5 C to 40 C All values are typical unless specified All specifications are subject to change without notice Product Calibration Fixture Model FCLCE 452 Frequency Range 10 kHz to 400 MHz Standard s MIL...

Page 11: ...Page 11 of 18 INSTRUCTION MANUAL SECTION 3 PRODUCT INFORMATION Rev090519...

Page 12: ...Page 12 of 18 INSTRUCTION MANUAL SECTION 3 PRODUCT INFORMATION Rev090519...

Page 13: ...Page 13 of 18 INSTRUCTION MANUAL SECTION 3 PRODUCT INFORMATION Rev090519...

Page 14: ...or conducted susceptibility tests These applications are discussed in more detail in the following sections The FCLCE 452 Fixture is specifically designed for use with the CLCE 452 The intent of the f...

Page 15: ...fixture with the opposite side terminated into 50 ohms while measuring the voltage present at the output of the probe The difference between the applied voltage and the measured voltage at any given f...

Page 16: ...sfer impedance factors include the insertion loss of the probe and also perform the function of converting the measured voltage quantity into a current quantity Based on the assumption that the probe...

Page 17: ...pair service or modify the instrument by personnel other than Com Power service representatives Under no circumstances does Com Power recognize or assume liability for any loss damage or expense arisi...

Page 18: ...ration please contact Com Power Corporation Any modifications or repairs performed on the unit by someone other than an authorized factory trained technician will void warranty The exterior surface ma...

Reviews: