10
Orion AQM/AQM+
____________________________________________________________________
Columbia Weather Systems, Inc.
Measuring Specifications
(AQM/AQM+)
Operating Conditions
Temperature: -22 to +104°F (-30 to +40°C)
Limited performance: -40 to +122°F (-40 to +50°C)
Relative Humidity: 15 to 95 %RH (non-condensing)
Pressure: 23.62 to 35.43 inHg (800 to 1200 hPa)
Temperature
Range: -40 to 185°F (-40 to +85°C)
Accuracy: @68°F (20°C) ±0.5°F (0.3°C)
Resolution: 0.1°F
Units Available: °F, °C
Relative Humidity
Range: 0 - 100%
Accuracy: 0 to 90%RH ±5%RH
90 to 100 %RH: ±8 %RH
Resolution: 0.1%
Units Available: %RH
Barometric Pressure
Range: 23.62 to 32.48 InHg (800 to 1100 hPa)
Accuracy: ±10 hPa
Resolution: 0.029 InHg (1 hPa)
Units Available: InHg, Kpa, mbar, hPa
Summary of Contents for Orion AQM