57
-
unscrew the used cartridge from the internal
cap (Fig. 84) and then screw in the new one;
84
-
screw up the internal cap having lubricated or replaced the sealing O-Rings if they are worn and
having lubricated the threads of the external cap using silicone grease.
WARNING
The used active carbon filter cannot be disposed of together with urban waste. To dispose of the active
carbon filter, follow the instructions given in chapter 10.2, “Disposal of waste products” with great care.
The refill hose must be in good condition especially in the area of the connections.
The plastic sheath that covers the hose must not show any signs of abrasion otherwise if any humidity
infilatrates, it could corrode the steel plait and reduce its resistance. The hose must be replaced
periodically (annually) and/or when it shows signs of wear. Failure to comply with this regulation could
cause serious danger to the operators. Make sure that the minimum radius of curvature of the hose is
not less than 250 mm.
To connect the hose, follow the instructions given in chapter 6.2.2, “Connecting the refill hose”.
11.7
11.7
11.7
11.7
11.7
Refill hose