Page 41
Ci Scanner Service Manual
12.
REMOVING AND REPLACING COMPONENTS
12.1.
MAIN TIMING BELT
12.1.1 Safety Precautions
Ensure the power is completely disconnected from the scanner unit.
Ensure the scanner is positioned on a stable maintenance platform.
12.1.2 Tools
7mm Nutdriver.
12.1.3 Associated Part Numbers
P003151 Main Timing Belt
12.1.4 Procedures
1. Remove left end cover as
in Chapter 11.1.
2. Loosen the locking nut on
the tension bar. Do not
allow the nut to come
completely off the end, as
the tension bar will fall
back inside the chassis.
3. Pull the belt over the lip of
the roller pulley as much
as possible and rotate the
roller pulley anti-clockwise
until the belt comes off
completely.