.05.
.06.
properly
·
Make sure the lens are in good condition. It’s recommended to replace the units if
there are any damages or severe scratch.
·
Make sure the fixture is operated by qualified personnel who knows the fixture
before using.
·
Keep the original packages if any second shipment is needed.
·
Don’t tr y to change the fixtures without any instruction by the manufacturer or
the appointed repairing agencies.
·
It is not in warranty range if there are any malfunctions from not following the
user manual to operate or any illegal operation, like shock short circuit, electronic
shock , lamp broke, etc.
when installing the fixture.
PHOTOMETRIC DATA
4
OPERATION INSTRUCTIONS
5
·
The moving head is for beam effect for on-site decoration purpose.
·
Don’t turn on the fixture if it’s been through severe temperature difference like
after transportation because it might damage the light due to the environment
changes. So make sure to operate the fixture until it is in normal temperature.
·
This light should be keep away from strong shaking during any transportation or
movement.
·
Don’t pull up the light by only the head, or it might cause damages to the
mechanical parts.
·
Don’t expose the fixture in overheat, moisture or environment with too much dust
when installing it. And don’t lay any power cables on the floor. Or it might cause
electronic shock to the people.
·
Make sure the installation place is in good safety condition before installing the
fixture.
·
Make sure to put the safety chain and check whether the screws are screwed
Cautions:
For added protection mount the fixtures in areas outside walking paths,
seating areas, or in areas were the fixture might be reached by unauthorized
personnel.
Before mounting the fixture to any surface, make sure that the installation area can
hold a minimum point load of 10 times the device’s weight.
Fixture installation must always be secured with a secondar y safety attachment, such
as an appropriate safety cable.
Never stand directly below the device when mounting, removing, or ser vicing the
fixture.
from a ceiling, or set on a flat level surface (see illustration below). Be sure this fixture
is kept at least 0.5m (1.5 ft) away from any flammable materials (decoration etc.).
Always use and install the supplied safety cable as a safety measure to prevent
accidental damage and/or injur y in the event the clamp fails.
Mounting points:
Overhead mounting requires extensive experience, including
amongst others calculating working load limits, a fine knowledge of the installation
material being used, and periodic safety inspection of all installation material and
the fixture. If you lack these qualifications, do not attempt the installation yourself.
Improper installation can result in bodily injur y.
Be sure to complete all rigging and installation procedures before connecting the
INSTALLATIONS
6
1147 / 12350
277 / 2985
123 / 1322
(FC/LUX)
2.5m (8.2ft)
5m (16.4ft)
7.5m (24.6ft)
ø 1.21 / ø 4.03
ø 2.42 / ø 8.06
ø 4.88 / ø 16.31
(m/ft)
0m (0ft)
Beam Diameter
15
°
15
°
Beam Angle LUX 0.0929=FC
×
Photometric Beam Angle Data