Collomix Rühr- und Mischgeräte Gmbh
Shaker
V
IBA
15
&
V
IBA
25
D-85080 Gaimersheim
Edition
2.3-05
19
7.4.3
Low/high clamping pressure changeover point
(SMALL POT HEIGHT)
*only VIBA 25
The VIBA is able to clamp large and small containers with two different clamping
pressures. The clamping pressure is automatically selected in accordance with the height
of the clamping plate.
Small containers (pots)
are securely held with relatively low clamping pressure. These
containers usually have thin walls and may burst under too high clamping pressure.
Small containers are clamped with the clamping pressure set in the menu point "DC-MOT
CLAMP LOW" (see 7.4.6).
Large containers (pots)
need a higher clamping pressure if they are to be held safely.
These containers are made to be sturdier and can withstand higher clamping pressures.
Large containers are clamped with the value set in the menu point "DC-MOT CLAMP
HIGH" (see 7.4.7).
The changeover point between low and high clamping pressure is set with the value
"SMALL POT HEIGHT".
The set value equals the opening of the mixing unit in
millimeters
above which the machine changes over from low clamping pressure (CLAMP
LOW) to high clamping pressure (CLAMP HIGH).
Set the CLAMP HEIGHT value so that the changeover point lies between a small and a
large container.
SMALL POT HEIGHT
+ 220 -
•
•
SMALL POT HEIGHT
+ 220 -
•
Set the small/large pot changeover point
Button I ( + ):
increase value
Button II ( - ):
decrease value
The set value equals the opening of the mixing
unit in mm.
•
•
Press button "E" to call up the next menu point.
7.4.4
Opening and closing the mixing unit
(DC-MOT FREERUN)
The clamp motor function is tested in the menu point
DC-MOT FREERUN.
DC-MOT FREERUN 3
CLS OPEN
•
•
DC-MOT FREERUN 3
CLS OPEN
•
Open and close the mixing unit by hand.
Button I (CLS):
close the mixing unit
Button II (OPEN): open the mixing unit
The mixing unit moves in the selected direction
as long as the button is pressed.
•
•
Press button "E" to call up the next menu point.
•