Care and maintenance
Repairs
Consump琀椀on material
Before performing any maintenance or cleaning work, always pull the power plug out of the
power supply socket.
Clean the machine immediately after use. Never clean it with running water. The mixing tool
can often be cleaned using just a little wet sand in the tub. Let the mixing tool run in it for just
a short time and it will be clean.
Keep the HEXAFIX coupling clean and freely moving at all times. Apply suitable grease (e.g.
MOXaktiv 250 from OKS; Molykote) to the hexagon mount of the coupling at regular intervals.
Keep the ventilation slits clean and clear at all times so that the machine can be properly
cooled. Blocked ventilation slits will lead to irreparable damage to the machine.
Make sure the tipping device and rollers run smoothly and make sure the brakes work properly.
Replace all damaged, bent or worn machine parts.
The mixing tool drive unit is equipped with self-deactivating carbon brushes. When the mini-
mum length is reached, the machine is switched off. The carbon brushes should only ever be
replaced by a qualified electrician.
Use only a genuine Collomix mixing tub to replace a worn mixing tub. Only by using this tub can
it be guaranteed that the machine will work properly.
Repairs or faults in the electrical equipment should only be dealt with by qualified personnel
or the Collomix maintenance service.
Only use original Collomix accessories and replacement parts.
DANGER
Danger to life caused by dangerous electric voltage
Never under any circumstances open any covers or safety devices on the machine. Repairs may
only be performed by trained, qualified personnel. All safety devices and electrical equipment
must be checked after repair work to ensure that they are in proper working order, and this
must be documented.
Never modify or alter any safety-critical parts!
Additional attachments are not allowed to have an adverse affect on safety and they must be
approved by the manufacturer.Hersteller genehmigt werden.
The following consump琀椀on material is available:
Part
Ref.no.
Mixing tub, 19 gals,
(without pouring spout)
70115
Mixing tool DLX 152 HF-VM
70100
Screen
71064
Pouring spout
71061