Care and maintenance
Troubleshoo琀椀ng
The mixer must always be disconnected from the power supply by pulling the mains plug prior
to any maintenance and cleaning work.
Always ensure ease of movement for all moving parts.
The mixer is largely maintenance-free. The drive sha昀琀 is supported by ball bearings with per
-
manent lubrica琀椀on.
Clean the machine immediately a昀琀er use. Do not let material deposits dry.
Remove the mixing tool from the hexagon sha昀琀 and clean it outside of the mixer.
Do not tap the mixing tool and mixing tub using a hammer. Bent mixing tools can lead to dam-
age to the device and poor mixing results.
Replace damaged, bent or worn machine parts.
Treat moving parts, such as the bo琀琀om segment slidegate, extendable discharge chute and
hexagons sha昀琀 from 琀椀me to 琀椀me with spray oil.
Malfunc琀椀on
Cause
Remedy
Machine does not start
• Supply cable too long and/or cable
cross-section too small
• Plug not inserted
• No mains voltage present
• Capacitor defective
• Check cable cross-section, must be AWG 16,
shorten supply cable
• Insert plug
• Check mains voltage
• Replace starting capacitor*
Machine switches off after
a short time , cannot be
switched on again
• Thermal overload protection trig-
gered (overload of the machine) -
-
only for TMX 1500
• Supply cable too long and/or cable
cross-section too small
• Cable was pulled from the mains
plug
• Voltage drop in the power supply
• Capacitor defective
• Let machine cool down (at least 2 min), reduce
mix as needed
• Check cable cross-section, must be AWG 16,
shorten supply cable
• Insert cable again
• Check mains voltage
• Replace starting capacitor*
Machine does not start up
when filled, remains at a
standstill
• Mixing quantity too high
• Mixed material too tough
• Reduce the material volume
* Work on live components may only be carried out by a quali昀椀ed electrician!