Opera琀椀on
X
Close the protec琀椀ve gra琀椀ng and make sure that it is locked.
X
Switch on the mixer. Press the green start bu琀琀on.
X
Fill the necessary amount of water into the mixing bucket.
X
If installed, switch on the vacuum cleaner.
X
Place the material sack with its broad side on the grid cover with the bag ripper and move
it back and forth slightly un琀椀l the sack is fully open. Gradually 昀椀ll the content of the bag
into the bucket.
X
Pay a琀琀en琀椀on during the mixing process to determine whether the material is mixed to a
su昀케cient extent.
X
To empty the mixing bucket, open the bo琀琀om segment slide using the lever.
X
Empty the mixed material into a bucket or wheelbarrow.
X
Press the red OFF bu琀琀on “0” to switch o昀昀 the machine. The machine comes to a stop.
The machine is 昀椀琀琀ed with a
protec琀椀on switch
. It switches the machine o昀昀 in the event of over
-
loading/overhea琀椀ng. Let the motor cool down and restart the machine.
The machine is fitted with an
undervoltage trigger
. If it triggers, the machine is stopped. This
may occur due to the following reasons:
• Voltage drop in the mains supply
• Supply cable too long
• Power supply disconnected
Restart after the malfunction is corrected.
IMPORTANT:
Observe the informa琀椀on in the technical data sheets of the material manufacturers.
The necessary mixing 琀椀me depends on the quan琀椀ty and viscosity of the material.
WARNING
Risk of injuries due to rota琀椀ng mixing tool.
Do not reach into the mixing drum or handle tools in the mixing drum during mixing.
ATTENTION
Only use the mixer for the tasks listed in chapter “Intended use”. Observe the safety infor-
ma琀椀on respec琀椀vely.
Removing the mixing tool
Unlock and open the cover with the protec琀椀ve gra琀椀ng.
The mixing tool rests on the hexagonal pin of the drive sha昀琀 without addi琀椀onal a琀琀achment.
You can easily li昀琀 the mixing tool o昀昀 of the sha昀琀. It may happen that you need to move the tool
back and forth a li琀琀le if it has stru琀琀ed apart.
The individual mixing paddles can be replaced. To do this, loosen the screw connec琀椀ons on the
arms of the mixing tool.