NOTE:

 It is important to ensure all elements: Hoses, Debris Screens and Inlet/Outlet Valves are properly aligned.

Operation

1) Open/unscrew the Air Purge Valve on the top of the Filter Pump; air is released as water fills the Filter Pump.

Note:

 If knob should become dislodged, simply place it back into the hole and turn clockwise to rethread air purge valve.

2) When water comes out of the Air Purge Valve screw it closed and wipe away any water.
3) Test the GFCI plug.

NOTE:

 It is imperative to check that the hydraulic connectors are not closed.

PEDESTAL FIXING

The filter pump must be vertically fixed on ground or a certain pedestal made of wood or concrete before use. There 

should be two holes 9mm in diameter on the pedestal, the space between which should be 166mm. Put filter pump on the 

pedestal and fix them together by fasten the bolts and nuts. All the pedestal parts should weigh over 18kgs at least to 

prevent the pump from accidentally falling.

390 166

390

250

166

2-M8 bolt

2-M8 nut

B

A

A

B

B

A

A

B

A. To test the GFCI plug, insert it into a grounding type receptacle.

B. Press the “RESET” button; the indicator turns red.

GFCI Test

RESET

TEST

RESET

TEST

RESET

TEST

A

B

C

D

7

NOTE: 

If the indicator light is not on, the test has failed.

C. Press the “TEST” button. The indicator turns off.

NOTE: 

If the indicator light is not off, the test has failed.

D. Press the “RESET” button, the indicator light turns red, and the filter pump is ready for use.

WARNING: 

RISK OF ELECTRIC SHOCK. THE GFCI MUST BE TESTED BEFORE EACH USE.

WARNING: 

DO NOT USE THE PUMP IF THE ABOVE TEST FAILS.

Please contact your local Bestway Customer Service.

NOTE: 

To prevent the risk of electrical shock, ensure your hands are completely dry when plugging-in the Filter 

Pump.

IMPORTANT: 

DO NOT DRY RUN THE FILTER PUMP -

 Make sure both the pool’s Inlet and Outlet valves 

are fully covered by water before operating the Filter Pump.

Maintenance

CAUTION: 

YOU MUST ENSURE THE FILTER PUMP IS UNPLUGGED BEFORE ANY MAINTENANCE OR 

STORAGE BEGIN S OR SEVERE RISK OF INJURY OR DEATH EXISTS.

1) Unplug the Filter Pump.

2) Loosen the Hose Clamps on the pool’s Inlet and Outlet Hoses by unscrewing the fly nut counter-clockwise.

3) Remove Debris Screens from the inside of the pool.

4) Replace the Debris Screens with the Stopper Plugs in the pool’s Inlet and Outlet Valves.

5) Unscrew the Filter Cap Retainer and remove the Filter Cap.

6) Clean the Filter Cartridge with a garden hose, if filter cartridge remains soiled or discolored, it is necessary to replace it with a 

new one.

7) Insert the cleaned (or new) Filter Cartridge; ensure it is centered in the Filter Pump.

8) Check that the Filter Cap Seal is in place.

9) Replace the Filter Cap and screw the Filter Cap Retainer into position.

10) Replace the Stopper Plugs with the Debris Screens in the pool’s Inlet and Outlet Valves. Tighten the Hose Clamps. 

Water will now flow to the pump.

11) Follow the PUMP INSTALLATION DIRECTIONS section to prepare the system for use.

IMPORTANT: 

For sanitary reasons we suggest replacing the Filter Cartridge with a new one every two 

weeks.

STORAGE

1) Unplug the Filter Pump.

2) Follow the instructions as previously outlined to stop water flowing to the Filter Pump and to remove the Filter Cartridge.

3) Discard the Filter Cartridge.

4) Detach all Hoses.

5) Dry all components thoroughly.

6) Store the filter pump in a dry location out of the reach of children. Storage temperature: 4-40

O

C (

39.2-104

O

F

)

Pump Warranty

For information concerning pump warranty please visit our website at: www.bestwaycorp.com

Summary of Contents for FlowClear 90402E

Page 1: ...MANUAL DO NOT RETURN THIS ITEM TO THE STORE OR WEBSITE WHERE IT WAS PURCHASED PLEASE VISIT BESTWAYCORP COM SUPPORT FOR QUESTIONS OR FOR DEFECTIVE OR WARRANTY CLAIMS Para la instrucci n en espa ol visi...

Page 2: ...test button The GFCI should interrupt power Push the reset button Power should be restored If the GFCI fails to operate in this manner the GFCI is defective If the GFCI interrupts power to the pump wi...

Page 3: ...t breaker and lock breaker door Failure to do so will result in increased risk of shock injury and possibly death DO NOT REMOVE THE GROUNDING PRONG OR MODIFY THE PLUG IN ANY WAY DO NOT USE ADAPTOR PLU...

Page 4: ...NSTRUCTIONS WARNING RISK OF ELECTROCUTION 1 Connect Only To Properly Grounded Outlet Do Not Remove Ground Pin 2 Inspect Cord Before Using Do Not Use If Cord Is Damaged 3 Keep Ground Fault Circuit Inte...

Page 5: ...ermined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the s...

Page 6: ...4 B B A P6362ASS16 P6019ASS16 P6132ASS16 P6132ASS16 A B A B B A B A B X2 B B A P61318ASS16 P6680ASS16 P6124ASS16 3 4 1 2 B A P6019ASS16 P6019ASS16 B A A B A B A B B A P61318ASS16 P6680ASS16 B A P6124A...

Page 7: ...check that the hydraulic connectors are not closed PEDESTAL FIXING The filter pump must be vertically fixed on ground or a certain pedestal made of wood or concrete before use There should be two hole...

Page 8: ...s with the Stopper Plugs in the pool s Inlet and Outlet Valves 5 Unscrew the Filter Cap Retainer and remove the Filter Cap 6 Clean the Filter Cartridge with a garden hose if filter cartridge remains s...

Page 9: ......

Page 10: ...ix Arizona 85034 United States of America Trademarks used in some countries under license to Bestway Inflatables Material Corp No 3065 Cao An Road Shanghai 201812 China Exported by Bestway Hong Kong I...

Reviews: