Coleman CM 01205-11 Operator'S Manual Download Page 5

 

BASIC COMPRESSOR FEATURES

 

 

A. ELECTRIC

 

MOTOR:

 The motor is used to power the pump. It contains a thermal overload protector 

and an automatic reset. If the motor overheats for any reason, the thermal overload protector will shut it 
down to prevent the motor from being damaged. The motor will automatically restart when it completely 
cools.  

 

B. AIR 

COMPRESSOR 

PUMP:

 The pump is used to compress the air and discharge it into the tank via 

the piston moving up and down in the cylinder. 

 

C. PRESSURE 

SWITCH:

 The switch is used to start or stop the air compressor and is operated manually. 

When in ON position, it allows the motor to start when the air tank pressure is below the factory set 
cut-in pressure and allows the motor to stop when the air tank pressure reaches the factory set cut-out 
pressure. ALWAYS set this switch to OFF when the unit is not being used, and before unplugging the 
unit. 

 

D. PRESSURE 

RELIEF 

VALVE: 

The valve is used to prevent system failures by relieving pressure from 

the system. When the pressure reaches the preset level, the pressure switch will not shut down the 
motor. It will automatically pop open or you can pull the ring on the valve to open. 

 

E. AIR 

PRESSURE 

REGULATOR: 

The regulator is used to adjust line pressure to the tool you are using. 

Turn the knob clockwise to increase pressure and counterclockwise to decrease pressure. 

 

   

WARNING

Never exceed the maximum working pressure of the tool. 

 

F.  TANK PRESSURE GAUGE: 

The gauge is used to measure the stored air pressure level of the tank. It 

is not adjustable by the operator, and does not indicate line pressure. 

 

G. REGULATED 

PRESSURE 

GAUGE: 

The gauge is used to measure the regulated outlet pressure. 

 

H. AIR 

LINE 

OUTLET: 

The outlet is used to connect 1/4” NPT air hose. 

 

I. 

AIR TANK DRAIN VALVE: 

The drain valve is used to remove moisture from the air tank after the unit is 

shut off. 

   

   

WARNING

Never attempt to open the drain valve when the tank pressure is over 10 PSI. 

 

J. AIR 

TANK: 

The tank is used to store the compressed air. 

 

K. POWER 

CORD: 

This product is for use on a nominal 115 volt circuit and should be grounded. A cord 

with a grounding plug, as illustrated must be used. Make sure that the product is connected to an outlet 
having the same configuration as the plug (see Figure 1). No adapter should be used with this product.   
Check with a licensed electrician if the grounding instructions are 
not understood, or if in doubt as to whether the product is properly 
grounded. Do not modify the plug provided. If it will not fit the outlet, 
have the proper outlet installed by a licensed electrician. 
 

   

DANGER

 

Improper installation of the grounding plug will result 

in a risk of electric shock. If repair or replacement of the cord or plug 
is necessary, do not connect the grounding wire to either flat blade 
terminal. The grounding wire is in the green outer surface. 

 

 

 

 

   

Grounded 
outlet 

Grounding Pin 

Plug 

- 5- 

Figure 1 

Summary of Contents for CM 01205-11

Page 1: ...Industry Group Ltd All Rights Reserved Coleman R and are registered trademarks of The Coleman Company Inc used under license 2010 The Coleman Company Inc 11GAL AIR COMPRESSOR 3 5HP 11 GALLON IMPORTANT...

Page 2: ...HOOTING CHART 9 EXPLODED VIEW PARTS LIST 10 WARRANTY 11 SPECIFICATION ITEM NO CM 01205 11 PUMP OIL LUBRICATED DIRECT DRIVE MOTOR 2 5 Continuous HP VOLTAGE AMPS PHASE 120 15 1 AIR TANK CAPACITY 11 GALL...

Page 3: ...t with moving parts could cause serious injury 5 RISK OF BURSTING Check the maximum pressure rating in the manual or the serial tag label Compressor outlet pressure must be regulated so as to never ex...

Page 4: ...F K A ELECTRIC MOTOR B AIR COMPRESSOR PUMP C PRESSURE SWITCH D PRESSURE RELIEF VALVE E AIR PRESSURE REGULATOR F TANK PRESSURE GAUGE G REGULATED PRESSURE GAUGE H AIR LINE OUTLET I AIR TANK DRAIN VALVE...

Page 5: ...ecrease pressure WARNING Never exceed the maximum working pressure of the tool F TANK PRESSURE GAUGE The gauge is used to measure the stored air pressure level of the tank It is not adjustable by the...

Page 6: ...ndle A by inserting the both ends into the base and secure with four 4 bolts B provided See Figure 5 7 Locate the compressor according to the following guidelines a Set the compressor in a position ne...

Page 7: ...e tank drain valve Turn clockwise 8 Turn the pressure switch to the ON position The unit will start and fill the tank to the cut out pressure and stop NOTE The pressure switch will restart the motor a...

Page 8: ...y and to clear the valve of any possible obstructions Daily Clean the air filter A dirty filter will reduce the unit s performance and life To avoid any contamination of the inside pump the filter sho...

Page 9: ...ve the pressure switch to the OFF position If the motor does not shut off unplug the air compressor If the electrical contacts are welded together replace the pressure switch Air compressor not large...

Page 10: ...assembly 6 1 Oil fill plug 7 1 Relief valve 8 1 Pressure switch 9 1 Adapter fitting 10 1 Regulator 11 2 Pressure gauge ITEM QTY DESCRIPTION 12 1 Handle 13 1 Pad kit 14 1 Drain valve 15 4 Bolt 16 4 Bo...

Page 11: ...f you feel you have a defective product please submit a copy of your receipt to the address below and call 1 855 900 2653 for instructions prior returning this item to the store or sending back to Gre...

Reviews: