FIRESTOP SPACERS: (V3600FS-8DM) 
 

Firestop spacers are required at each point where the chimney 
penetrates a floor space.  Their purpose is to establish and 
maintain the required clearance between the chimney and the 
combustible materials. 
When the pipe passes through a framed opening into a living 
space above, the firestop must be placed onto the ceiling from 
below as shown in figure 21. 
 

 

INSTRUCTIONS WHEN ELBOW OFFSET OF 
CHIMNEY IS NEEDED: (30E-8DM) 
 

TO INSTALL ELBOWS 
1.

 

To achieve desired offset, you may install combinations 
of 12”, 18”, 24”, 36” and 48” length of double wall pipe 
(SEE SINGLE OFFSET CHART, FIGURE 22 & 24). 

 

 OFFSET CHART (22-28 FT. SYSTEM HEIGHT) 

 

2.

 

Chimney weight above offset rests on return elbow. 
Straps must be securely nailed to rafters or joists (see 
figure 22, details a & b). 

 

3.

 

Maximum length of pipe between supports (return elbow 
or 12S-8DM) is 6’ of angled run. Maximum of two (2) 6’ 
angled run sections per chimney system (see figure 24). 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
*For systems with 2 elbow sets, the minimum height is 22 ft. 
The maximum height for any system is 28 ft. 
 

 
 
 
 
All joints between offset 
should be secured with two 
screws, only on the outer 
pipe, and shall not penetrate 
the inner stainless. 
 
 
 
 
 

Figure 23

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 22 

Figure 24       *TYPICAL OFFSET INSTALLATIONS 

Figure 21 

OFFSET

RISE

A

B

48"

36"

24"

18"

12"

4 - 3/8

16 -3/8

9 - 3/4

25 - 1/2

1

12 - 3/4

30 - 3/4

1

15

34 - 3/4

1

18

40

1

1

21 - 1/4

46 - 1/4

1

23 - 3/4

49 - 1/4

1

1

27 - 3/4

56 - 3/4

1

30

60 - 3/4

1

1

33

66 1

1

36

71

1

1

38 - 1/4

75

2

41 - 1/4

80 - 1/4

1

1

1

45

86 - 3/4

2

46 - 3/4

89 - 1/2

1

1

1

51

97

1

1

53 - 1/4

101

2

1

56 - 1/4

106 - 1/4

2

59 - 1/4

111 - 1/2

1

1

1

61 - 3/4

115 - 1/2

2

1

64 - 3/4

120 - 3/4

2

1

68 - 1/4

127

1

2

70

130

2

1

1

74 - 1/4

137 - 1/2

1

2

1

76 - 3/4

141 - 1/2

1

2

1

79 - 3/4

146 - 3/4

4

ELBOW SET ONLY

CHIMNEY LENGTH

Summary of Contents for 36MWL

Page 1: ...le not for purpose of resale from the manufacturer permanently located manufactured mobile home where not prohibited by local codes A DESA hood must be installed when using a vent free gas log heater...

Page 2: ...HEARTH EXTENSION PG 3 6 OUTSIDE AIR KIT INSTALLATION PG 4 7 FAN KIT ASSEMBLY PG 4 8 CHIMNEY PIPE INSTALLATION PG 4 5 6 9 TERMINATIONS PG 6 10 FINISHING YOUR FIREPLACE PG 7 11 MANTELS PG 7 12 GLASS DO...

Page 3: ...will make installation easier 4 An outside air kit is included with this fireplace For more details refer to section on outside air kit installation on page 4 WARNING DO NOT INSTALL IN A BEDROOM MINIM...

Page 4: ...28ga minimum to prevent corrosion STEP 6 Using screws or nails secure the fireplace to the framing through flanges located on the sides of the fireplace see figure 4 HEARTH EXTENSION A hearth extensi...

Page 5: ...contents of these kits are listed under accessories on page 11 Most chimney systems for manufactured houses require a standard straight installation as described in this section If an uncommon offset...

Page 6: ...it onto the firestop using holes provided see figure 10 The row of holes on the sides of the thimble is provided to allow for pitch variances Position the firestop assembly and thimble to desired angl...

Page 7: ...but can be installed after the home is sited TERMINATIONS SPARK ARRESTOR The fireplace system must be terminated with the listed round top terminations In any case refer to the installation instructi...

Page 8: ...16 from the wall the fireplace is installed in This combustible material can butt up against the side of the fireplace i e 1 from the fireplace opening OPERATING GUIDELINES AND MAINTENANCE INSTRUCTION...

Page 9: ...ce cement Install the decorative gas appliance or cap off gas line if desired The gas pipe is intended for connection to an unvented vent free or a decorative gas appliance vented gas log If you wish...

Page 10: ...d to rafters or joists see figure 22 details a b 3 Maximum length of pipe between supports return elbow or 12S 8DM is 6 of angled run Maximum of two 2 6 angled run sections per chimney system see figu...

Page 11: ...to lock it in place see figure 25 FOR FURTHER OPERATING GUIDELINES INSTRUCTIONS AND WARRANTY INFORMATION PLEASE REFER TO YOUR HOMEOWNERS GUIDE OR CONTACT YOUR AUTHORIZED DEALER TECHNICAL SERVICE You m...

Page 12: ...CPMH A ACB 8 vent kit 9 vent kit 9 vent kit 36 8DM 36 Double Wall Pipe 2 1 2 24 8DM 24 Double Wall Pipe 1 3 0 18 8DM 18 Double Wall Pipe 0 0 2 FST A Adjustable Firestop Thimble 1 1 1 6F 8 Roof Flashi...

Reviews: