background image

 

TIMER BUTTON 

6

 

 
 

Used to initiate the AUTO ON start 
time and AUTO OFF stop time 
program, in conjuction with the 

(+)

 

(-)

 buttons. The timer on/off 

indicator light illuminates under the 
timer on/off settings.

 

 

SWING BUTTON 

7

 

 

 

(Applicable to the models with 
auto swing feature only)

 

Used to initiate the Auto swing 
feature. When the operation is ON, 
press the SWING button can stop 
the louver at the desired angle.

 

 

LED DISPLAY  

8

 

 

Shows the set temperature in "  " or

 

 

"

 

" and the Auto-timer settings.  

 

While on DRY and FAN modes, it 
shows the room temperature.

 

FOLLOW ME/TEMP SENSING

 

 

(OPTIONAL)

 

9

 

 

NOTE:This feature can be activated 
from the remote control ONLY.

 

 

The remote control servesas a 
remote thermostat allowing for the 
precise temperature control at its 
location. To activate the Follow 
Me/Temp Sensing feature, point the 
remote control towards the unit and 
press the Follow Me/Temp Sensing 
button. The remote display is actual

 

 

temperature at its location. The 
remote control will send this signal 
to the air conditioner every 3 
minutes interval until press the 
Follow Me/Temp Sensing button 
again.If the unit does not receive the 
Follow Me/Temp Sensing signal 
during any 7 minutes interval, the 
unit will beep to indicate the Follow 
Me/Temp Sensing mode has ended

 

 

 

 

 
 

2.2 OPERATION INSTRUCTIONS

 

 

COOL OPERATION

 

FAN OPERATION

 

 

 Press the "MODE" button until the 

"COOL" indicator light comes on.

 

 

 Press the ADJUST buttons "+" or " - 

" to select your desired room 
temperature. The temperature can be 
set within a range of 62 -88 17 -30 .

 

 

 Press the "FAN SPEED" 

button to choose the fan speed.

 

 

 Press the "MODE" button until the 

"FAN " indicator light comes on.

 

 

 Press the "FAN SPEED" 

button to choose the fan speed.

 

The temperaturecannot be adjusted 

 Do not put the duct to window.

 

Summary of Contents for MPPD-12CRN1

Page 1: ...COLDWAVE Portable Air Conditioner Model MPPD 12CRN1 12000 BTU h 110V 1Ph 60Hz R410A...

Page 2: ...Features 4 Speed Fan Ion Generator Sleep Mode Timer Auto Cool Dry Mode Swing Function Follow Me Temperature Sensor Swing Button LED Display Note Cooling Only No heat function...

Page 3: ...1 DIMENSION H W D Unit Dimension W H D mm inch Single hose 454 17 9 700 27 6 365 14 4 small body Single hose 467 18 4 765 30 1 397 15 6 Double hose 467 18 4 765 30 1 478 18 8...

Page 4: ...tor is energized and will help to remove pollen and impur ities from the air and trap them in the filter Press it for 3 seconds again to stop the ION feature UP AND DOWN BUTTON 4 Used to adjust increa...

Page 5: ...llow Me Temp Sensing feature point the remote control towards the unit and press the Follow Me Temp Sensing button The remote display is actual temperature at its location The remote control will send...

Page 6: ...TO mode you can not select the fan speed TIMER OPERATION When the unit is on press the Timer button will initiate the Auto off stop program the TIMER OFF indicator light illuminates Press the UP or do...

Page 7: ...mode 3 ELECTRONIC FUNCTION 3 1 Abbreviation T1 Indoor room temperature T2 Temperature of evaporator T3 Temperature of condenser TS The setting temperature S1 Water level swicth 3 2 Main Protection 3 2...

Page 8: ...0 6 27 9 1245 129 2 54 2 959 33 8 1 33 3269 82 4 28 8 7198 131 55 2 8442 35 6 2 31 5635 84 2 29 8 3357 132 8 56 2 7382 37 4 3 29 9058 86 30 7 9708 134 6 57 2 6368 39 2 4 28 3459 87 8 31 7 6241 136 4 5...

Page 9: ...igh Mid Low The TS can t be controlled because of the LED displaying as T1 The ION TIMER functions are valid at the fan only mode 3 3 3 Cooling mode function requirement The speed of indoor fan can be...

Page 10: ...working And outdoor fan will stop for a delay of 5 seconds b When T1 59 15 outdoor fan operates and compressor will restart operation after 15seconds The speed can t be controlled at drying mode and i...

Page 11: ...TIMER functions are valid at the heating mode 3 4 6 Heating mode function requirement for Heat Pump TS range is 62 88 17 30 T1 TS 41 5 compressor operates T142 8 6 41 5 T1 42 8 6 86 30 86 30 100 4 38...

Page 12: ...122 50...

Page 13: ...vaporator temperature sensor error E3 Condenser temperature sensor error Causation a Port of temperature sensor is loose b Temperature sensor is bad c Circuit component is bad Solution a Check the con...

Page 14: ...f it can not resume after 2 minutes please replace the PCB 4 2 Protection code and Solution P1 Water full protection Causation Water in tank is full Solution Connect the drain hose and drain the colle...

Page 15: ...move the heat sources if possible c Connect the duct and make sure it can function properly d Decrease the TS e Clean the air filter Noisy or vibration Causation The ground is not level or not flat en...

Page 16: ...5 INTERNAL STRUCTURE Temperature sensor Evaporator Centrifugal fan Compressor Water pump Indoor fan motor Capacitor of compressor Condenser Water level sensor...

Page 17: ...Display board Temperature sensor Display board Water level switch Relay Louver motor Outdoor motor Indoor motor Power on off Capacitor of fan motor Electronic control box...

Page 18: ...ly 1 5 Horizontal louver 6 Cover of electronic control box 1 6 Bracket 7 Suction pipe assembly 1 7 Gear wheel 8 Discharge pipe assembly 1 7 Gear wheel 10 Capillary assembly 1 8 Louver motor 11 Evapora...

Page 19: ...fugal fan 27 7 Bracket of water level sensor 32 6 Power cord 27 8 Micro switch 33 Capacitor box 27 9 Bracket of Micro switch 34 Capacitor of compressor 27 10 Dobber case 35 Fasten board of Capacitor 2...

Page 20: ...2 8 Capacitor box 27 17 Top cover of Shaded pole motor 3 Dobber 27 18 Bottom cover of Shaded pole motor 5 Electronic control box assembly 27 19 Drain Connector 5 1 Electronic control box 27 20 Connec...

Page 21: ...Servair Limited 45 Market Street Marabella Trinidad Tel 1 868 658 1911 1 868 658 1910 1 868 658 2010 Fax 1 868 658 3012 Email paul servair com...

Reviews: