![Colby Instruments 21090000 Operating And Programming Manual Download Page 10](http://html1.mh-extra.com/html/colby-instruments/21090000/21090000_operating-and-programming-manual_2635110010.webp)
Chapter 3 .0
Using the Front Panel Connections
3 .1 Overview of the Front Panel Connections
The Trombone
IN
connector begins the signal path and continues through the internal top half of the electromechanical trombone and
out across the
vertical jumper
and back through the bottom half of the trombone and exiting at the
OUT
connector.
Model XT-100 single trombone
3 .2 Trombone Only Model XT-100-625P
The total delay range is from 0 to 625.0 ps offered through both halves of the trombone. The hybrid stepper motor offers 0.50 ps
step resolution.
3 .3 Models XT-100-001N thru XT-100-100N
Total delay is offered through the electromechanical trombone and delays sections.
4
COLBY INSTRUMENTS XT-100 VERSION 1.0 OPERATING AND PROGRAMMING MANUAL