COLASIT AG
Plastics construction
CH-3700 Spiez
Phone +41 (0)33 655 61 61 Fax +41 (0)33 654 81 61
TD-000 800-E
Edition 10/2019, Subject to alteration
Copyright by COLASIT AG Spiez
Page 13
8
Operating instructions
To operate the fan, we recommend the production of process instructions. These documents are intended to
simplify repetitive workflows, reduce the risk of incorrect operation and are a valuable aid for training and
when personnel changes occur.
If the fan must be qualified, process instructions are an absolute prerequisite.
You will find important instructions on how to produce process instructions in various chapters of this
operating manual.
To help ensure the safe operation of the fan, COLASIT offers the service of
reviewing process instructions prepared by the operator
9
Logbook
For your own safety and as an aid to personal responsibility, we recommend the keeping of a logbook for the
entire period during which the fan is in service.
All events should be recorded in the logbook.
In case of damage and also in case of an accident, this document is the first source of information.
For example, enter the date and your signature:
-
Start and end of a work cycle
-
Special events, even if they do not concern the fan itself (e.g. power failure, alarm)
-
Change of supervision staff (e.g. in case of shift operation),
-
Repairs carried out and spare parts installed,
-
Putting out of operation,
-
Special instructions,
-
etc.
10
Disposal
Before disposing of plastics and other components (complete or as broken parts), please clean them as
necessary to avoid any danger to the environment.
Dispose of the components properly. Instruct a waste disposal company to do this or return them to us for
disposal.
11
Troubleshooting
If faults occur, we recommend you identify and clear them using the following table.
If the fault cannot be cleared, please contact our customer service department.
Fault
Possible causes
Remedy
Fan not running smoothly
Impeller imbalance
Rebalance by specialist
company
Impeller caked up
Clean carefully rebalance if
necessary
Material corrosion on impeller
due to aggressive conveyed
medium.
Consult the manufacturer
Impeller deformed due to high
temperature.
Consult the manufacturer.
Install new impeller.
Check bearings
V-belt drive not correctly
aligned.
Adjust belt drive
V-belt torn or damaged
Normal wear and tear
Replace V-belts in sets
V-belt pretensioned too strongly
Tension replacement belt to
manufacturer’s specifications