![COINWASH T3300S Service Manual Download Page 61](http://html.mh-extra.com/html/coinwash/t3300s/t3300s_service-manual_2635027061.webp)
487 0329 21
27.5
27. Sensors and overheating thermostats
27
Service
manual
Outlet air - Thermistor element (NTC sensor)
Function
The sensor measures the temperature in the outlet air and the signal is returned to the
main circuit board.
The main circuit board turns the heating unit off when the outlet air thermistor indicates
that the required temperature has been reached.
The resistance of this device is normally 80 to 100 kOhms at 20°C (68F) and it drops as
its temperature increases.
The sensor A is mounted on the same bracket as the outlet air overheating thermostat.
Error codes
The following error codes are related to this section.
E02, E04, E18
Refer to section 12 for more information.
A