To make things easier, the revision and internal cleaning there should be a free space at 
least 25 cm between the protection cover (pos.13, figs. 7, 

page 22

) of the electrical water 

heater and any fixed obstacle. 
 

1.4. Placement and securing 

 
To anchor the thermo to the wall (see elevations on 

page 13

), use 2 tacks and screws 

which are sufficient to bear the weight of the thermo when filled with water (see 
“characteristics” table 

page 3

). 

 
 

1.5. Installation of water system 

 

When installing the water piping, follow the basic rules for preventing corrosion: “Do not 
use copper or brass before iron or steel in the water circulation direction”. To avoid 
galvanic pairs and their destructive effect, screw two tubes of the thermo (as seen in the 
drawings in figure 7, 

page 22)

 and deploying Teflon tape, the insulating sleeves (pos.12) 

supplied along with the thermo. 
Screw the insulating sleeve of the cold water entry direction (blue) of the thermo, the 
hydraulic security unit with an emptying device (pos. 8. figs. 7, 

page 22

) supplied with the 

thermo. Install a cutting key alongside the water pumping tube as seen in the drawings 
(figs. 7 pos. 10, 

page 22

). 

Connect the hot water distribution pipe to the insulating sleeve of the hot water conduit of 
the site. 
The unit or hydraulic safety valve, supplied with the thermo, contains a retention and 
overpressure valve. The latter opens as a maximum at 8 bars. If the pressure in the water 
installation exceeds 5 bars, install a pressure reducer as indicated in the standard. 
The widespread use of anti-return valves in the stipulations of the sanitary water system, 
bringing about a strong increase in pressure by dint of the heating process; in these cases 
it is vital to conduct the drain of the safety valve to an excavation pipe provided with a 
siphon (figs. 7, pos.9, 

page 22

); this tube shall be put in the open air and shall be installed 

on a continuous slope until below. 
 
The emptying of the lever can be carried out using the corresponding thermo (1). 
 
Check the watertightness of all connections 
 

1.6. Description of safety valve 

 
1. - Appliance for emptying water from the thermo 

 

Entered direction 

 

cold water 

2. - Outlet of mouth or emptying.  
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

         

 

 

 
 

 

 

 

 

 

 

 

 

 

         

2    

 

 

4

Summary of Contents for TNC 10

Page 1: ...ELECTRICAL WATER HEATER Installation Use and conservation TNC 10 TNC 15 TNC 30 TNC 50 TNC 80 TNC 80 H TNC 100 TNC 100 H TNC 150 TNC 150 H ...

Page 2: ...e established collection centres The correct ollection of the appliance allowing the recycling of the appliance at the end of its working life in line with the environment contributes to avoiding any possible negative impacts on the environment and health nd fosters the recycling of the materials whereof the product is made up c a For more detailed information about the collection systems availabl...

Page 3: ...egulations such as the Low Voltage Electrotechnical Regulations the Technical Building Code and the local Regulations applicable In particular for installation in a bathroom or toilet the volumes established by the Low voltage electrotechnical Regulations shall be respected No switches current outlets nor lighting appliances shall be installed in prohibition volume fig 1 page 12 No switches shall ...

Page 4: ...e pos 8 figs 7 page 22 supplied with the thermo Install a cutting key alongside the water pumping tube as seen in the drawings figs 7 pos 10 page 22 Connect the hot water distribution pipe to the insulating sleeve of the hot water conduit of the site The unit or hydraulic safety valve supplied with the thermo contains a retention and overpressure valve The latter opens as a maximum at 8 bars If th...

Page 5: ...the regulation thermostat pos 11 figs 7 pages 22 1 9 Conservation It is vital that the Technical Assistance Service SAT annually revises its thermo to eliminate the lime deposited in the heating element pos 5 figs 7 page 22 and check the status of the magnesium anode pos 5 figs 7 page 22 If the water in your area is very hard and corrosive you should ask for more frequent revisions If the magnesiu...

Page 6: ...paña Estamos a su disposición en el teléfono 902 40 20 10 NADIE MEJOR QUE COINTRA CONOCE SU TERMO Asegure la vida y buen funcionamiento de su aparato COINTRA le ofrece la seriedad y garantía que sólo puede dar el Servicio Técnico Oficial del Fabricante Solicite información en su teléfono amigo 902 40 20 10 6 ...

Page 7: ...7 ...

Reviews: