I. INSTALLATION, USE AND CONSERVATION INSTRUCTIONS
The smooth operation of your thermos depends not only on the quality of the product but
also on its correct installation by a qualified professional.
1.1. General characteristics
MODELS: TNC-10, TNC-15, TNC-30, TNC-50, TNC-80, TNC-80 H, TNC-100, TNC-100 H
TNC-150, TNC-50 H
NOMINAL CAPACITY LITRES: 10, 15, 30, 50, 80, 100, 150
WEIGH WHEN FULL OF WATER* KG: 16, 23, 43, 69, 104, 104, 128, 128, 187, 187
ADJUSTABLE WATER TEMPERATURE °C: UP TO 75° C
MAXIMUM WORK PRESSUR bar: 8 bar
ELÉCTRICAL VOLTAGE: V-Hz 230 V / 50 Hz
ELÉCTRICAL POWER: W 1.200 W 1.500 W
* To be borne in mind when carrying out anchorage to the wall
1.2. Installation instructions
Installation shall comply with official regulations such as the “Low Voltage Electrotechnical
Regulations”, the Technical Building Code and the local Regulations applicable. In
particular for installation in a bathroom or toilet, the volumes established by the “Low
voltage electrotechnical Regulations” shall be respected.
• No switches, current outlets nor lighting appliances shall be installed in prohibition
volume (fig 1)
page 12
.
• No switches shall be installed in the protection volume (fig.2),
page 19
, but safety current
outlets may be installed.
1.3. Product localisation
The thermo should be located as close as possible to the hot water outlets to avoid heat
losses in the piping.
The TNC electrical water heater shall always be installed vertically, with the water
connections below (see fig. 7
), page 19,
except the models TNC 80 H, TNC 100 H and
TNC 150 H, that will always settle in horizontal, also with the water connections down (to
see fig 8),
page 16
3
Summary of Contents for TNC 10