4.4 Technical data table
Data
Units
CPA 6
CPA 11
CPA 14
Product identification codes G20
GCA1HKKF
GCL1MKKA
GCI1PKKF
Product identification codes G31
GCA1HLKF
GCL1MLKA
GCI1PLKF
Countries of destination
ES - PT - IT - FR - BE
Gas category
II2H3+ (ES-PT-GB) / (IT) / II2E+3+ (FR) / I2E+ (BE) / I3+ (BE)
Maximum heat capacity
kW
11.8
21.1
26.8
Q
Minimum heat capacity
kW
6.3
8.1
10.7
Q
Maximum heat capacity
kW
10.4
18.9
23.8
Minimum heat capacity
kW
5.4
7.0
9.3
Performance at max. power
%
87
87
87
Burner injectors G20
n. x Ø
14 x 0.82
24 x 0.85
28 x 0.85
Gas supply pressure G20
mbar
20
20
20
Maximum gas delivery G20
m3/h
1.25
2.23
2.84
Minimum gas delivery G20
m3/h
0.67
0.86
1.13
Burner injectors G230
n. x Ø
14 x 0.95
24 x 0.95
28 x 0.95
Gas supply pressure G230
mbar
20
20
20
Maximum gas delivery G230
m3/h
0.97
1.73
2.20
Minimum gas delivery G230
m3/h
0.52
0.66
0.88
Burner injectors G31/G30
n. x Ø
8 x 0,49 / 6 x 0,47
18 x 0.49 / 6 x 0.47
16 x 0.49 / 12 x 0.47
Gas supply pressure G31/G30
mbar
37
37
37
Max. gas delivery G31/G30
m3/h
0.92
1.64
2.08
Min. gas delivery G31/G30
m3/h
0.49
0.63
0.83
NOx emission class
-
6 (<56 mg/kWh)
NOx
Max. operating pressure
bar
10
10
10
PMS
Min. operating pressure
bar
0.2
0.2
0.2
DHW delivery ∆25º
l/min
6.0
10.8
13.6
DHW delivery ∆30º
l/min
5.0
9
11.4
Degree of protection
IP
X4D
Supply voltage
V/Hz
3V =
Absorbed electrical power
W
/
/
/
Empty weight
Kg
8.5
9.50
13.50
Type of unit
B11BS