High-Speed Output - NPN Configuration
The Breakout cable can be used to connect to an NPN-compatible PLC input. Connect HS OUT 0 or HS OUT 1 directly to
the PLC input. When enabled, the output pulls the PLC input down to less than 3VDC. For more information, refer to the
High-Speed Output - PNP Configuration
The Breakout cable can be used to connect to a PNP-compatible PLC input. Connect HS OUT 0 or HS OUT 1 directly to
the PLC input. When enabled, the output pulls the PLC input up to greater than 21VDC. For more information, refer to the
22
Specifications