Specifications 

 

Feature 

Description 

Inputs and Outputs 

• 

Eight independent discrete inputs, optically isolated. 

• 

Eight independent discrete outputs, optically isolated. 

Operating Voltage 
(Field Side) 

• 

5v to 24v DC. 

Power 

• 

+5v DC, supplied from the In-Sight processor. 

Maximum Output Current 

• 

15 mA (sink or source). 

ON State Voltage Drop 

• 

0.8v DC @ 10 mA, 2.6v DC @ 15 mA. 

OFF State Leakage Current 

• 

100 

µ

A; maximum @ 15v DC. 

Output Delay 

• 

ON: 6 

µ

Sec. 

• 

OFF: 130 

µ

Sec @ 5 mA; 95 

µ

Sec @ 10 mA; 85 

µ

Sec @ 15 mA. 

Input Resistance 

• 

~ 1000 Ohms. 

Input State Current 

• 

ON: 3.5 to 15 mA. 

• 

OFF: 500 

µ

A. 

Input Delay 

• 

ON: 30 

µ

Sec @ 3.5 mA; 8 

µ

Sec @ 15 mA. 

• 

OFF: 45 

µ

Sec @ 3.5mA; 80 

µ

Sec @15 mA. 

Field Wiring Size 

• 

26 to 12 AWG 

Terminal Block Torque 

• 

Maximum 7 in-lb (0.8 N-M). 

Cable 

• 

2.13 m (7 ft), supplied 

Mechanical 

• 

Dimensions: 120 mm (4.75 in) wide x 60 mm (2.35 in) high x 83 mm (3.25 in) deep. 

• 

#3 DIN Rail mountable. 

Environmental 

• 

Operating Temperature: 0 to 50

°

C (32 to 122

°

F). 

• 

Operating/Storage Humidity: 5 to 95% non-condensing. 

• 

Storage Temperature: -20 to 85

°

C (-4 to 185

°

F). 

 

 

60.0 mm 

(2.35 in) 

120 mm 
(4.75 in) 

83 mm 

(3.25 in) 

Figure 8 – Dimensions

P/N 597-0015-01 

Summary of Contents for In-Sight I/O Expansion Module

Page 1: ...ignments p 6 Schematics p 7 Specifications p 8 Product Contents The I O Expansion Module kit Cognex P N CIO 2350 00 includes the following components I O Expansion Module P N 800 5712 2 2 1 m 7 0 ft I...

Page 2: ...RNAL I O CAUTION The I O Expansion Module must have the same ground potential as the In Sight processor s chassis Any difference in potential can damage the equipment If you connect a ground wire to t...

Page 3: ...button to open the System menu 3 Highlight Settings and press the A1 button to open the Settings menu 4 To configure a discrete input line highlight Discrete Input and press A1 to open the Discrete In...

Page 4: ...og 2 Configure the selected output line as needed and press OK to close the Discrete Output dialog You write values from the worksheet to the discrete output through the WriteDiscrete function NOTE In...

Page 5: ...Output 5 2 Input 1 15 Output 6 3 Input 2 16 Output 7 4 Input 3 17 Power 5v DC fused at 0 5 A 5 Input 4 18 Power 5v DC fused at 0 5 A 6 Input 5 19 Ground 7 Input 6 20 Ground 8 Input 7 21 Ground 9 Outpu...

Page 6: ...Pin INPUTS LED Anode OUTPUTS Collector Pin INPUTS LED Cathode OUTPUTS Emitter 1 IN 0 OUT 0 9 IN 0 OUT 0 2 IN 1 OUT 1 10 IN 1 OUT 1 3 IN 2 OUT 2 11 IN 2 OUT 2 4 IN 3 OUT 3 12 IN 3 OUT 3 5 IN 4 OUT 4 13...

Page 7: ...llowing schematics apply only to the external discrete inputs and outputs on the I O Expansion Module For information on the built in discrete inputs and outputs on the In Sight processor see the Inst...

Page 8: ...Delay ON 6 Sec OFF 130 Sec 5 mA 95 Sec 10 mA 85 Sec 15 mA Input Resistance 1000 Ohms Input State Current ON 3 5 to 15 mA OFF 500 A Input Delay ON 30 Sec 3 5 mA 8 Sec 15 mA OFF 45 Sec 3 5mA 80 Sec 15...

Reviews: