Note
: When using the vision system with the Breakout cable, the polarity of the and TRIGGER- pins is
not critical. However, when using an optional I/O module, the polarity of the and TRIGGER- pins should
be observed.
Encoder Inputs (In-Sight 5604 Only)
The Breakout cable can be used for communication between the vision system and a single or quadrature encoder. For
single encoders, the ENCODER A pin must be used. For quadrature encoders, the ENCODER A or ENCODER B pin can
be used. The signal from the encoder must be +24VDC. For more information, refer to
Specification
Description
Voltage
ON: 20 to 28VDC (24VDC nominal)
OFF: 0 to 3VDC (9.6VDC nominal threshold)
Current
ON: 84 to 118µA
OFF: < 11µA
Resistance: ~233 kOhms
Maximum Encoder Frequency
99.2KHz (assuming a 50/50 duty cycle)
25