Installing In-Sight
®
1720 Series Wafer Readers
15
3.4 Connect the Network and Breakout Cables
The wafer reader has two RJ-45 connector ports: the Network Port and the Breakout Port
(see Figure 3-4). The Network Port provides the Ethernet connection for network
communications. The Breakout Port supplies connections for the 24VDC power source, I/O,
acquisition trigger, and serial communications.
Figure 3-4: Location of RJ-45 Ports
3.4.1 Connect the Network Cable
•
If you are connecting to an Ethernet switch/router,
plug one of the RJ-45
connectors of a CAT5 straight-pinned cable or crossover cable into the Network Port
(labeled Ethernet) and plug the other end into an available port on the switch/router.
•
If you are connecting directly to a wafer reader from a remote host,
plug one
end of a CAT5 network cable or crossover cable into the wafer reader’s Network Port
(labeled Ethernet); plug the other end into the remote host’s Ethernet port.
3.4.2 Connect the Breakout Cable
The breakout cable provides access to the wafer reader’s power, serial communications, and
I/O lines. The RJ-45 connector on this cable is “keyed” to the notch in the Breakout Port, and
cannot be inadvertently plugged in to the Network Port. See Section 5.2.2: Breakout Port Pin
Assignments on page 33 for the Breakout Cable’s wiring details.
To connect the wafer reader using the optional 1350 Breakout Module, refer to Appendix B.
Summary of Contents for In-Sight 1720 Series
Page 1: ...1 ...
Page 2: ......
Page 6: ...Precautions iv ...
Page 10: ...List of Figures viii ...
Page 12: ...List of Tables x ...
Page 22: ...Set Up the PC 10 ...
Page 54: ...Connecting the Breakout Module 42 ...
Page 56: ...P N 597 0047 01 www cognex com Installing the In Sight 1720 Series Wafer Reader ...